Table 1-2: Meter specifications
(continued)
Liquid meter specifications
Analog Input(s)
(2) 4-20 mA
•
AI-1 Temperature
•
AI-2 Pressure
Note
The analog-to-digital conversion accuracy is
within ±0.05% of full scale over the operating
temperature range.
Note
AI-1 and AI-2 are electronically isolated and
operate in sink mode. The input contains a
series resistance so HART
®
Communicators can
be connected to configure sensors.
A 24 Volt DC power supply is available to
provide power to the sensors.
Digital, analog, and frequency outputs
Installation manual
Introduction
3-9000-771
May 2019
Installation manual
21