Figure 3-8: Transmitter electronic enclosure security latch
A. Transmitter Electronics Enclosure end cap
B. Security latch
Procedure
1. Rotate the end cap on Transmitter Electronics Enclosure _H1 clockwise fully closing
and compressing the end cap seal. Install the Security latch using a 3mm Allen
wrench.
2. Install the security seal wire into and through one of the two holes in the end cap.
Choose holes that minimize counterclockwise rotation of the end cap when the
security wire is taut (maximum wire diameter .078 inch; 2.0mm).
Installation manual
Electrical Installation
3-9000-771
May 2019
Installation manual
57