WARNING
HAZARDOUS VOLTAGE INSIDE
Do not open in flammable gas area. Disconnect all power to the meter.
Failure to comply can result in death or serious injury.
3. Check the serial number tag on top of the Transmitter Electronics Enclosure.
Remove the end cap with the serial tag marked with _H1 (nearest its conduit entry)
to gain access to the transmitter electronics.
4. Pull the wires into the enclosure.
5. Complete the field connection wiring according to the system wiring diagram (see
6. Repeat
for the Transmitter Electronics Enclosure with the
serial tag marked with _H2.
7. Apply electrical power to the system to ensure the field connections are working
correctly. Replace the end caps and allow the system to run for the time specified
by the customer (usually one week) and an electrician have fully tested the
connections. After the Acceptance Test is witnessed and approved, seal the
conduit.
8. Power down the system and apply the sealing compound to the conduit and allow
to set in accordance with manufacturer specifications.
9. If required, install the security latches and wire seals on the Transmitter Electronics
Sealing the Transmitter Electronics Enclosure
).
10. If required, install the wire seals through the socket head bolts on the Base
Enclosure (see
Sealing the Transmitter Electronics Enclosure
).
11. Connect electrical power to the system.
12. Set or configure the meter using Daniel MeterLink. For additional installation
information refer to the system wiring diagram (see
),
Daniel MeterLink
Softeware for Gas and Liquid Ultrasonic Meters Quick Start Manual
(P/N 3-9000-763).
Use the Daniel MeterLink Field Setup Wizard to complete the configuration. Also
see,
Field Setup Wizard using Daniel MeterLink
in this manual.
3.4.2
Startup for systems using flame-proof cable
WARNING
HAZARDOUS VOLTAGE INSIDE
Do not open in flammable gas area. Disconnect all power to the meter.
Failure to comply can result in death or serious injury.
Procedure
1. Check to make certain that all field wiring power is turned
OFF
.
2. Check the serial number tag on top of the Transmitter Electronics Enclosure.
Remove the end cap with the serial tag marked with _H1 (nearest its conduit entry)
to gain access to the transmitter electronics.
Electrical Installation
Installation manual
May 2019
3-9000-771
44
3818 LNG Liquid Ultrasonic Meter
Summary of Contents for Daniel 3818
Page 2: ...2 ...
Page 10: ...Contents Installation manual May 2019 3 9000 771 x 3818 LNG Liquid Ultrasonic Meter ...
Page 26: ...Introduction Installation manual May 2019 3 9000 771 26 3818 LNG Liquid Ultrasonic Meter ...
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......