![Emerson Daniel 3818 Installation Manual Download Page 79](http://html.mh-extra.com/html/emerson/daniel-3818/daniel-3818_installation-manual_103510079.webp)
Figure 4-20: 3818 transmitter field wiring conduit entries
A. Field wiring conduit entries (8)
5. Wire Analog Input 1 (AI1) and Analog Output 1 (AO1) as shown in
Figure 4-21: Field Communicator wiring diagram for the 3818 LNG Meter
6. Use the leads provided with the Field Communicator to connect to your device.
7. Press and hold the
Power
button on the Field Communicator until the green light
blinks.
8. Use the touch screen on the Field Communicator, the keypad or use the stylus to
navigate through the device menus.
9. Refer to the Menu tree in Section D.1.1 of the Daniel HART Field Device
Specification manual (P/N 3-9000-762) for the device fast key sequences. Included
in the menu tree are:
Installation manual
Configuration
3-9000-771
May 2019