![Emerson CSI 9420 Reference Manual Download Page 80](http://html.mh-extra.com/html/emerson/csi-9420/csi-9420_reference-manual_104608080.webp)
3.2.5
Attach the sensors
shows a typical accelerometer, mounting stud, and mounting pad used with the
CSI 9420. The mounting pad is only necessary when doing an epoxy mount.
Accelerometer, mounting stud, and optional mounting pad
Figure 3-3:
A.
accelerometer
B.
mounting stud (included with the accelerometer)
C.
mounting pad
Prerequisites
Whenever possible, mount sensors to the machine while pulling cables. If you have to
mount the sensor at another time, secure the bundled cable to the machine and protect it
from damage.
Procedure
1.
Using a plant-approved cleaner/degreaser, remove any lubricating fluid used during
the tapping process and if necessary, clean the mounting stud threads.
2.
Rub a small amount of semi-permanent thread locker onto the mounting location.