AGL_Stream_ST_A2L_A1_4M_6M_EN_Rev00
27
4.5.3.2
CoreSense Protection
– Wiring diagrams
Part-winding motors can be connected direct-on-line or part-winding start.
Legend
A1 ....... CoreSense protection module
K1 ........ Contactor M1
A2 ....... OPS2 Oil pressure switch
K4 ........ Contactor M1 for second part winding
A5 ....... Compressor terminal box
M21 ..... Fan motor / condenser
F6 ....... Fuse for control circuit
R2 ....... Crankcase heater
F7 ....... Fuse for control circuit
Y21 ...... Solenoid valve capacity control 1
F8 ....... Fuse for control circuit
Y22 ...... Solenoid valve capacity control 2
F10 ..... Thermal protection switch M21
Y3 ........ Solenoid valve unloaded start
Figure 32: Wiring diagram
– Part-winding motors (AW…)