Sentronic
HD
INSTALLATION
MANUAL
AVENTICS™
4
Visit our website at Emerson.com/AVENTICS or contact us at (800) 972-2726
1.2 Operating Elements
1. Power supply, 8-pin male
connector M12
2. LC display
3. Control panel
4. Programming interface (Ethernet IP)
5. Pressure supply
6. Pressure outlet
7. Exhaust
8. Ground connection M4 thread
1.3 Operating Modes
Shut-off:
If the setpoint falls below 0.5 %, the pilot valves are switched off and the valve is fully exhausted.
Overtemperature:
If the temperature of the internal control electronics exceeds 100°C, the operating mode is switched to
AUTOSAFE.
Autosafe:
If the coil current exceeds a certain value, dependent on the mechanics, for more than 20 seconds, the output
current is limited to max. 70% to prevent the valve from overheating.
1
2
3
5
8
4
7
6