background image

Sentronic

HD

INSTALLATION 

MANUAL

AVENTICS™

3

Visit our website at Emerson.com/AVENTICS or contact us at (800) 972-2726

1. Description

The 

S

entronic

HD

 with integrated digital control loop combines the latest in pneumatics technology with intelligent 

electronics. The 

S

entronic

HD

 series allows precise control of pressure, flow, force, velocity and displacement or angle 

positions.
Cascaded control allows setting up complex control loops using the 

DaS-HD Software 

(Data Acquisition Soft-ware). 

Digital control offers many advantages during installation and start-up of the 

S

entronic

HD

 valve and ex-tended 

possibilities to adapt it to various applications.

•   Digital pressure control in a closed loop: An internal pressure sensor measures the inlet/

outlet pressure. The outlet pressure is adjusted in real time.

•   The control parameters can be changed with the 

DaS software:

 This flexibility allows the 

valve to be adapted to the most various applications, and its response time, overshoot and 
precision to be optimised.

•   After having set the optimum parameters, you can save them in a project file for your 

personal use or send them to our Product Support for future serial production.

1.1  How to Order 

S

entronic

HD

 - Digital Electronic Pressure Regulator

G  616  A  4  0  0  0  0  A00  06

Thread Connection

G = ISO 228 

Product Series

616

Revision

=  Initial Release

Size

4 = G1/4 + pressure hold

5 = G1/4 + pressure release

Setpoint

0 = 0-10V

1 = 0-20mA

2 = 4-20mA

3 = PWM - Frequency*

Feedback

0 = 0-10V

1 = 0-20mA

2 = 4-20mA

Options

A00 =  Standard

Pressure Range

03 = 0…3 bar

06 = 0...6 bar

10 = 0...10bar

V1 = -1...(+3bar)

Input 2 / Display w/ Buttons

0 = Standard NC + Display

2 = Analog IN 2 + Display

4 = Digital IN 2 + Display

6 = Frequency IN + Display*

Output 2

0 = NC

1 = Digital OUT

2 = Analog OUT2

* If Setpoint PMW-Frequency is selected, frequency input is not avaliable at IN 2

Summary of Contents for Aventics SENTRONIC HD 616 Series

Page 1: ...GB IM14277 GB R01 Series616 Installation Manual SentronicHD Digital Electronic Pressure Regulator ...

Page 2: ...89 392 EEC Annex II B is available on request Please provide ordering code and serial numbers of products concerned DECLARATION OF INCORPORATION according to Machinery Directive 89 392 EEC Annex II B We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other machinery and that it must not be put into service...

Page 3: ...time The control parameters can be changed with the DaS software This flexibility allows the valve to be adapted to the most various applications and its response time overshoot and precision to be optimised After having set the optimum parameters you can save them in a project file for your personal use or send them to our Product Support for future serial production 1 1 How to Order SentronicHD ...

Page 4: ...st 8 Ground connection M4 thread 1 3 Operating Modes Shut off If the setpoint falls below 0 5 the pilot valves are switched off and the valve is fully exhausted Overtemperature If the temperature of the internal control electronics exceeds 100 C the operating mode is switched to AUTOSAFE Autosafe If the coil current exceeds a certain value dependent on the mechanics for more than 20 seconds the ou...

Page 5: ... varistor must be used 4 A shielded cable must be used for protection against interference and EMC 5 The valve body must be grounded with the earthing terminal PE dia M4 Ethernet IP Programming Interface M12 Cable Plug 4 pole D coded M12 male connector 8 pin A coded View on male connector the device is equipped with a female connector The use of a shielded cable is recommended View on valve Pin De...

Page 6: ...ed to the PMR In order to avoid damaging the sensor the supply pressure must always be less than the maximum inlet pressure MAP see Technical Characteristics Setpoint span The pressure span of the setpoint can be changed via the DaS HD software Switch Module 1 to Rescale in the Parameter Setpoint section The span is between 10 and 150 Offset Adjustment SHUT OFF Max outlet pressure PMR 50 PMR 50 mV...

Page 7: ...d or not Class 5 to ISO 8573 1 Ports G1 4 Max Inlet Pressure 174 psi 12 bar Pressure Range see Section 1 1 Temperature Fluid 32 122 F 0 50 C Temperature Ambient 32 122 F 0 50 C Hysteresis 0 25 of span Linearity 0 25 of span Reliability 0 25 of span 4 2 Specification Nominal Diameter DN Stabilized Voltage Max Power W Max Cur rent mA Insulation Class Degree of Protec tion Flow Electrical Connection ...

Page 8: ...ct must be returned to the factory for repair WARNING NOTES These products are intended for use in industrial compressed air systems only Do not use these products where pressures and temperatures can exceed those listed under SPECIFICATIONS Please also see the corresponding product specification sheets Before using these products with fluids other than those specified for non industrial applicati...

Page 9: ... or care required 7 Dimensions mm Weight kg Weight 1 6 kg 20 7 143 0 3 42 95 122 3 16 55 59 5 0 2 G1 4 x 10 18 0 2 50 0 2 G1 4 x 10 29 75 0 2 43 0 2 78 26 89 6 12 29 75 0 2 35 0 2 G1 4 x 10 51 0 2 14 0 2 46 0 2 19 0 2 14 0 2 46 0 2 14 0 2 46 0 2 68 75 29 75 PE M12 female connector M12 connector 8 pins 4 pin Ethernet M4 x 8 1 M4 x 10 M4 x 10 2 3 M4 x 10 M4 x 10 ...

Reviews: