CAUTION! Dangerous operating conditions may occur when using the programming interface on the valve as the valve may possibly 
not react to the analog setpoint any more.
Provide for protection against uncontrolled movement of equipment when putting the valve into operation and before making any 
modifications to the valve settings.

NOTICE

The information in this manual is subject to change without notice.
In no event shall ASCO NUMATICS be liable for technical or editorial errors or omissions. Neither is any liability assumed for accidental or 
consequential damages arising out of or in connection with the supply or use of the information contained herein.
THIS MANUAL CONTAINS INFORMATION PROTECTED BY COPYRIGHT. NO PART OF THIS DOCUMENT MAY BE PHOTOCOPIED OR REPRODUCED IN 
ANY FORM OR MANNER WHATSOEVER WITHOUT PRIOR WRITTEN PERMISSION FROM ASCO NUMATICS.
COPYRIGHT © 2015 - ASCO NUMATICS - All rights reserved.

E S D

This product complies with the essential requirements of the EMC Directive 89/336/EEC and its amendments. It is CE-approved. A separate Declaration 
of Conformity is available on request.
A separate Declaration of Incorporation relating to the EU Directive 89/392/EEC Annex II B is available on request. Please provide ordering code and serial 
numbers of products concerned.

DECLARATION OF INCORPORATION

according to Machinery Directive 89/392/EEC, Annex II B

We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other  

machinery and that it must not be put into service until the machinery into which it is to be incorporated has been declared in conformity  

with the provisions of Council Directive 89/392/EEC, Annex IIB.

Handling, assembly and putting into service and all settings and adjustments must be done by qualified, authorised personnel only.

This product contains electronic components sensitive to electrostatic discharge. 
An electrostatic discharge generated by a person or object coming in contact with 
the electrical components can damage or destroy the product.
To avoid the risk of electrostatic discharge, please observe the handling 
precautions and recommendations contained in standard EN 100015-1. Do not 
connect or disconnect the device while it is energised.

C AU T I O N

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC SENSITIVE DEVICES

!

1

1.1

1.2

1.3

2

3

4

4.1

4.2

5

6

7

Table of Contents

Sentronic

HD

 Description 

3

 

Catalogue number 

3

 

Operating Elements 

4

 

Operating Modes 

4

 

Electrical Connection 

5

 

Analog Setpoint - Outlet Pressure 

6

 

Technical characteristics 

7

 

Fluid characteristics 

7

 Specifications 

7

 Accessories 

8

 

Maintenance and care 

9

 

Dimensions and weight 

9

Summary of Contents for Aventics SENTRONIC HD 616 Series

Page 1: ...GB IM14277 GB R01 Series616 Installation Manual SentronicHD Digital Electronic Pressure Regulator ...

Page 2: ...89 392 EEC Annex II B is available on request Please provide ordering code and serial numbers of products concerned DECLARATION OF INCORPORATION according to Machinery Directive 89 392 EEC Annex II B We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other machinery and that it must not be put into service...

Page 3: ...time The control parameters can be changed with the DaS software This flexibility allows the valve to be adapted to the most various applications and its response time overshoot and precision to be optimised After having set the optimum parameters you can save them in a project file for your personal use or send them to our Product Support for future serial production 1 1 How to Order SentronicHD ...

Page 4: ...st 8 Ground connection M4 thread 1 3 Operating Modes Shut off If the setpoint falls below 0 5 the pilot valves are switched off and the valve is fully exhausted Overtemperature If the temperature of the internal control electronics exceeds 100 C the operating mode is switched to AUTOSAFE Autosafe If the coil current exceeds a certain value dependent on the mechanics for more than 20 seconds the ou...

Page 5: ... varistor must be used 4 A shielded cable must be used for protection against interference and EMC 5 The valve body must be grounded with the earthing terminal PE dia M4 Ethernet IP Programming Interface M12 Cable Plug 4 pole D coded M12 male connector 8 pin A coded View on male connector the device is equipped with a female connector The use of a shielded cable is recommended View on valve Pin De...

Page 6: ...ed to the PMR In order to avoid damaging the sensor the supply pressure must always be less than the maximum inlet pressure MAP see Technical Characteristics Setpoint span The pressure span of the setpoint can be changed via the DaS HD software Switch Module 1 to Rescale in the Parameter Setpoint section The span is between 10 and 150 Offset Adjustment SHUT OFF Max outlet pressure PMR 50 PMR 50 mV...

Page 7: ...d or not Class 5 to ISO 8573 1 Ports G1 4 Max Inlet Pressure 174 psi 12 bar Pressure Range see Section 1 1 Temperature Fluid 32 122 F 0 50 C Temperature Ambient 32 122 F 0 50 C Hysteresis 0 25 of span Linearity 0 25 of span Reliability 0 25 of span 4 2 Specification Nominal Diameter DN Stabilized Voltage Max Power W Max Cur rent mA Insulation Class Degree of Protec tion Flow Electrical Connection ...

Page 8: ...ct must be returned to the factory for repair WARNING NOTES These products are intended for use in industrial compressed air systems only Do not use these products where pressures and temperatures can exceed those listed under SPECIFICATIONS Please also see the corresponding product specification sheets Before using these products with fluids other than those specified for non industrial applicati...

Page 9: ... or care required 7 Dimensions mm Weight kg Weight 1 6 kg 20 7 143 0 3 42 95 122 3 16 55 59 5 0 2 G1 4 x 10 18 0 2 50 0 2 G1 4 x 10 29 75 0 2 43 0 2 78 26 89 6 12 29 75 0 2 35 0 2 G1 4 x 10 51 0 2 14 0 2 46 0 2 19 0 2 14 0 2 46 0 2 14 0 2 46 0 2 68 75 29 75 PE M12 female connector M12 connector 8 pins 4 pin Ethernet M4 x 8 1 M4 x 10 M4 x 10 2 3 M4 x 10 M4 x 10 ...