Configuration Parameters
Volume
Calculation Method
Select method for volume calculation based on tank shape or
a strapping table. Strapping table requires entering
level-volume pairs in a table.
Diameter (L1)
The diameter of the tank.
Length (L2)
The length (or height if the tank is shaped as a vertical
cylinder) of the tank, measured between tank ends.
Strapping Table
Use a strapping table if a standard tank type does not provide
sufficient accuracy. Use most of the strapping points in
regions where the tank shape is non-linear. A maximum of 20
points can be added to the strapping table.
If tank type Strapping Table was chosen, enter how many
entries you will use and the actual level and volume points.
The strapping points must be entered such that the first point
corresponds to the lowest level, and the last point
corresponds to the topmost level of the tank.
Actual tank bottom may look like this
Using only 3 strapping points results in a level-to-volume
profile that is more angular than the actual shape
Using 6 of the points at the bottom of the tank yields a
level-to-volume profile that is similar to the actual tank bottom
STRAPPING POINTS
Summary of Contents for 3308A Rosemount 3308 Series
Page 2: ......
Page 6: ...vi Reference Manual 00809 0100 4308 Rev BA Title Page December 2014 ...
Page 12: ...vi Reference Manual 00809 0100 4308 Rev BA Table of Contents December 2014 Table of Contents ...
Page 14: ...2 Reference Manual 00809 0100 4308 Rev BA Section 1 Introduction December 2014 Introduction ...
Page 52: ...40 Reference Manual 00809 0100 4308 Rev BA Section 3 Installation December 2014 Installation ...
Page 80: ...68 Reference Manual 00809 0100 4308 Rev BA Section 5 Operation December 2014 Operation ...
Page 196: ...4 Reference Manual 00809 0100 4308 Rev BA Index December 2014 Index ...
Page 197: ......