113
Reference Manual
00809-0100-4308, Rev BA
Appendix A: Reference Data
December 2014
Reference Data
Total probe length
This is defined from the Upper Reference Point to the end of the probe (weight included, if
applicable).
Figure A-9. Total Probe Length
Select the probe length according to the required measuring range (the probe must be hung
and fully extended through the entire distance where level readings are desired).
Cut-to-fit probes
All probes can be cut in field except for the PTFE covered probe. However, there are some
restrictions for the coaxial probe: Probes over 4.1 ft (1.25 m) can be cut up to 2 ft (0.6 m).
Shorter probes can be cut to the minimum length of 1.3 ft (0.4 m).
Minimum and maximum probe length
Flexible Single Lead: 3.3 ft (1 m) to 55.8 ft (17 m)
Rigid Single Lead (0.3 in./8 mm): 1.3 ft (0.4 m) to 9.8 ft (3 m)
Rigid Single Lead (0.5 in./13 mm): 1.3 ft (0.4 m) to 19.7 ft (6 m)
Flexible Twin Lead: 3.3 ft (1 m) to 55.8 ft (17 m)
Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m)
Probe angle
0 to 90 degrees from vertical axis
Tensile strength
Flexible Single Lead: 2698 lb (12 kN)
Flexible Twin Lead: 2023 lb (9 kN)
Total Probe Length
Upper Reference Point
NPT
BSP/G
Flange
Tri-Clamp
Summary of Contents for 3308A Rosemount 3308 Series
Page 2: ......
Page 6: ...vi Reference Manual 00809 0100 4308 Rev BA Title Page December 2014 ...
Page 12: ...vi Reference Manual 00809 0100 4308 Rev BA Table of Contents December 2014 Table of Contents ...
Page 14: ...2 Reference Manual 00809 0100 4308 Rev BA Section 1 Introduction December 2014 Introduction ...
Page 52: ...40 Reference Manual 00809 0100 4308 Rev BA Section 3 Installation December 2014 Installation ...
Page 80: ...68 Reference Manual 00809 0100 4308 Rev BA Section 5 Operation December 2014 Operation ...
Page 196: ...4 Reference Manual 00809 0100 4308 Rev BA Index December 2014 Index ...
Page 197: ......