133
Reference Manual
00809-0100-4308, Rev BA
Appendix A: Reference Data
December 2014
Reference Data
Figure A-15. Coaxial Probe
12 (297.2)
3.9 (100.2)
2.8 (71.3)
External antenna
(option WK)
Min. Ø 1.2 (30)
Metallic contact with
nozzle or tank allowed
Ø 1.1 (28)
Min. 0.2 (5)
1.1 (27)
BSP-G 1 in., s52
BSP-G 1½ in., s60
2.4 (62)
Thread sealing
Min. 8 (200)
Chamber/pipe
Min. Ø 1.3 (32)
NPT 1 in., s52
NPT 1½ in., s52
NPT 2 in., s60
1
.9 (
4
7)
2
.4 (
6
2)
3.4 (86)
4.3 (110)
L
20 ft.
(6 m)
Min. 0
to tank wall
7.8 (198)
Nozzle diameter
Dimensions are in inches (millimeters).