![EmerCom Technologies EMCS Series User Manual Download Page 13](http://html1.mh-extra.com/html/emercom-technologies/emcs-series/emcs-series_user-manual_2400079013.webp)
EMCS User Guide
- 13 -
6. Programming
6.1 Summary Table
The following section 6.2 provides more detailed information on each command.
Cmd #
Command
Range
Default
1
Learn Mode
- prompted to select
Operating Mode
0 = Lobby Mode (automatic if no phone
lines are available)
1 = TEL Mode (if 1 or 2 phone lines)
2 = Intelli-Split (if 1 or 2 phone lines)
N/A
2
Operating Mode
0 = Lobby Mode
1 = TEL Mode
2 = Intelli-Split Mode
1
3
Phone Lines Available
1 digit; values 0,1,2
1
4
Active Stations
0 – 6 (or 1-12 with EMCS-EXP)
1,2
5
Inactive Stations
0 – 6 (or 1-12 with EMCS-EXP)
3,4,5,6
6
Serial Number Playback Replay only
Pre-set
7
Main Firmware Version
Replay only
Pre-set
8
Alarm Status Playback
Replay only, one or more of the following
“NO MAINS POWER”
“NO BATTERY”
“LOW BATTERY”
“CHARGING BATTERY”
“NORMAL”
“PHONE LINE FAULT”
“STATION NUMBER #n FAULT”
N/A
9
Access Code
5 digits; values 1,2,3,4,5,6,7,8,9,0
12345
10
Language
0 = English
1 = French
0
14
Auto Answer
0 = OFF (ignore incoming on phone line)
1 = ON
1