The  auxiliary  catalytic  filter  consisting  of  the  highest  quality  natural  processed  coal  (grade  A 
hydroanthracite) serves for advanced water treatment from the oxidized organic and the chloroorganic 
compounds  (including  the  herbicides,  pesticides,  surfactants,  phenols,  antibiotics,  antidepressants, 
hormones). 
The  auxiliary  electrokinetic  filter  consisting  of  the  purest  natural  mountain  quartz  serves  for  the 
advanced  treatment  of  water  from  the  mechanical  impurities,  heavy  metals,  iron,  manganese  and 
hydrogen sulfide. 
 

Useful information 

 
The purification and electrical treatment of water in the anode and cathode chambers are highly 
efficient and safe. The water treatment processes are identical to natural ones but they are ac-
celerated tens of thousands of times due to the use of the latest technologies and electrochemical 
modules. 

The  catalytic  and  electrokinetic  filters  work  in  "purity".  They  are  located  after  the  anodic          
destruction of microbes, microbial toxins and biofilms which significantly increases their   ef-
ficiency and service life. Therefore the filter elements in the EMERALD are protected from the 
reproduction of microbes, fouling with the harmful biofilms and water contamination by the 
microbial toxins! 
The latest technologies used in the EMERALD allow you to get the clean and useful antioxidant 
water while maintaining a neutral level of acid-base balance (pH level). The antioxidant water 
with the neutral pH level is suitable for regular use in the composition of the usual dietary. Due 
to the similarity with the internal media of a human body such water is instantly absorbed by 
the body and holistically restores it. 

 

 

Summary of Contents for Home 4

Page 1: ...PASSPORT AND OPERATION MANUAL EMERALD HOME 4 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...

Page 2: ...e connection above the sink 10 Connection of diverter to the tap 10 Connection of the device to the electric network 11 6 OPERATION OF THE DEVICE 12 Cold tap water supply to the device 12 LED indicati...

Page 3: ...e nature Reproducing the most complex natural processes of water purification and treatment has become possible due to the creation of highly reliable electrochemical modules which are the main elemen...

Page 4: ...the water in the form of aerosol to moisturize the skin Moisturizing masks with the use of antioxidant water will have the special effect Pets and Plants the pets will prefer the antioxidant water to...

Page 5: ...re ac celerated tens of thousands of times due to the use of the latest technologies and electrochemical modules The catalytic and electrokinetic filters work in purity They are located after the anod...

Page 6: ...ified from free chlorine and chlororganic compounds u Improves the taste of water and eliminates the unpleasant odors due to the anodic removal of phenols and hydrogen sulfide Fig 3 Cathodic chamber o...

Page 7: ...thorized service center In order to reduce the risk of fire or electric shock it is strongly recommended not to disassemble the electronic components of the device u Avoid the rough handling with the...

Page 8: ...er elements and the electro chemical module is required see the section MAINTENANCE OF THE DEVICE u Do not use the first 30 liters of purified water immediately after connecting the device or after wa...

Page 9: ...and the parts included in the kit to connect the device in accordance with the diagram in Fig 7 ATTENTION Before starting the device connec tion procedure be sure to familiarize yourself with the bas...

Page 10: ...ct the tube to the fitting the following actions should be done u Insert the white tube until it stops in the hole of the fitting If the connection is right then the tube enters the fitting hole by 15...

Page 11: ...device 8 On off button flushing device 9 Tube for supplying tap water to the device 10 Tube of the outlet of purified water from the device Connection of diverter to the tap To install the divertor on...

Page 12: ...them During device pay attention to the fact that the inlet and outlet tubes pass freely along radii that exclude kinks Connection of the device to the electric network The EMERALD device is connecte...

Page 13: ...gin without proper pre filtration and disinfection Cold tap water supply to the device Fig 10 Water supply using the regulator on the diverter To enable the device in the OPERATION mode it is necessar...

Page 14: ...RATION mode and the drinking water quality has returned to normal Some features of the OPERATION mode u If the STANDBY mode idle of the device is less than 8 hours then when it is turned on the green...

Page 15: ...y 4 months or after 1 200 liters of the purified water whichever comes earlier The EMERALD automatically monitors the volume of purified water and it notifies you about the need for flushing u After 8...

Page 16: ...device back into the flushing device Maintenance of the EMERALD device is carried out in accordance with the diagram on Fig 11 Preparation of citric acid washing solution To carry out the flushing pro...

Page 17: ...nnections must be securely locked The device must be in STANDBY mode and be connected to a power source The flushing device should be located on a flat and stable surface on the countertop next to the...

Page 18: ...HING mode is non volatile and has priority That is when the network disappears and when it reappears the device will automatically enter the stage of the FLUSHING mode from which it was removed by dis...

Page 19: ...ents 1 Provide the necessary pressure in the water supply line see Table 5 2 Flush the device with citric acid solution see the section MAINTENANCE OF THE DEVICE The citric acid washing solution is no...

Page 20: ...ication corrective actions or maintenance performed by any person other than the authorized representative of the warranty service and maintenance service of the manufacturer or official trading partn...

Page 21: ...s for refusing by the representative of the manufacturer to connect the device as well as provide with the service and warranty service In the case of self installation and service of the device the m...

Page 22: ...ater temperature 1 30 Water supply line pressure MPa 0 1 0 4 Total mineralization of supplied tap water ppm 100 350 pH of supplied tap water 6 9 Efficiency of anodic oxidation of bivalent iron ions wi...

Page 23: ...MERALD HOME 4 device 1 2 Power supply adapter 1 3 Network cable for power supply 1 4 Diverter for water tap with a set of nozzles 1 5 Flushing device with a set of hoses 1 6 Set of connecting tubes 1...

Page 24: ...acture the EMERALD as well as to provide them with service and warranty service EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary power...

Page 25: ...24 APPENDIX No 1 CERTIFICATES 1 CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001 2015 ISO 9001 2015 2 CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...

Page 26: ...25 3 EXPERTS REPORT ISSUED BY ROSPOTREBNADZOR...

Page 27: ...26 4 VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 5 DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...

Reviews: