background image

18

19

Accessories

How to install your Ultra Delphi

Faucet Accessories

Ionizer Accessories 

pH test kit

Collet Release tool

Flexible Hose

Diverter Valve

T- Valve

Dust Pre-Filter

Color chart

Manual

Wall Mount Sheet

PE Hose(1/4”)

(Tap Water Supply Hose)

PE Hose(1/4”)

(Acidic / Ionizer Water Supply Hose)

PE Hose(5/16”)

(Alkaline Water Supply Hose)

Small Acidic

Water Fitting

Large Alkaine

Water Fitting

Alkaline Water outlet adapter
(Please connect to top cap of the ionizer
for installation Faucet.)

Circle Plate

Gasket

(Installed under the Faucet)

Allen Tool

Faucet Body

1/4”-1/4”

5/16”-5/16”

WARNING : Incorrect installation could void your valuable warranty - professional installation is recommended.

All the fittings are push in style fittings. To attach the hoses to any fitting 
firmly insert the end of the hose into the fitting. Pull firmly to check to 
connection - you should not be able to pull the hose out. 
To release the hose from the fitting, use the provide collet release tool to 
depress the spring loaded ring protruding from the end of the fitting while 
pulling the hose out.
[Online videos are available showing the use of quick-connect fittings.]

Installation Method 

1

2

3

4

5

Acidic Water

Alkaline Water

Tap Water
Direction

Ionizer inlet

fitting Direction

Data Cable

1.5” [30mm]

NUT

1/4” Tube

(Tap Water)

1/4” Tube

(Ionizer Inlet)

1/4” Tube

(Acidic Water)

5/16” Tube

(Alkaline Water)

Data Cable

Red

Grey

White

White

Use appropriate tools to make 1.5”(30mm) diameter hole in the 
location where you will install the faucet. 
Make sure the faucet location will allow both spout to reach 
the sink.(Fig.1)

Unscrew circle plate from faucet body.

Place the faucet in the hole ensuring the gasket comes
between the faucet and your counter/sink top. (Fig.2)

Thread the circle plate on to the faucet body under
the sink secure the faucet. (Fig.3)

Connect the 1/4” small Acidic and Water fittings
and 5/16” large Alkaline Water fitting to the
corresponding faucet hoses. (Fig.4)

Fig.1

Fig.2

Fig.3

Fig.4

Method 1 : Under the sink with Faucet

Summary of Contents for AlkaViva ULTRA DELPHI

Page 1: ...This provides the electrodes with longevity built to last at least 20 years The titanium is coated with platinum for excellent yet durable conductivity Advanced Computerized PCB Hi Tech Microcomputer...

Page 2: ...r system in the world Your new UltraDelphi undersink ionizer is designed to provide you with many years of the cleanest healthiest and most functional water available Your new UltraDelphi undersink is...

Page 3: ...Use it while brushing your teeth Gargle with it and use it as a natural mouth wash The Acid Water has both antiseptic and antibacterial properties It also has an astringent effect and can be used for...

Page 4: ...failure to do so may result in electric shock or fire Do not wash your ionizer by immersion or by pouring water over the main body always unplug your ionizer while cleaning the casing Clean with damp...

Page 5: ...a doctor If the liquid gets in the eyes flush immediately and thoroughly with cool water call a doctor If spilled or dropped on your body wash if off immediately Make sure to keep the pH reagent liqui...

Page 6: ...of water you have selected on the machine FND Display Easily Identifies Your Selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum p...

Page 7: ...stainless steel Alkaline water outlet For optional counter top installation 1 2 3 4 Flow Control Knob 5 6 7 8 9 11 12 13 14 15 10 11 6 8 7 13 14 12 10 Main switch AC Power cord Filter cover 15 9 Calc...

Page 8: ...s selected a blue number 1 4 will indicate which level When Acid Water is selected an orange number 1 4 will indicate which level Filter life indicator Counts filter usage in a digital display Filter...

Page 9: ...ator If Alkaline Water is selected the BLUE indicator will be lit Acidic Water display indicator If Acidic Water is selected the ORANGE indicator will be lit Filtered Water display indicator It Filter...

Page 10: ...elease the hose from the fitting use the provide collet release tool to depress the spring loaded ring protruding from the end of the fitting while pulling the hose out Online videos are available sho...

Page 11: ...should not be able to pull the hose out Connect 5 16 Alkaline Water Hose to the large fitting attached to the corresponding faucet hose identified in Fig 7 above Pull firmly to check to connection you...

Page 12: ...itting and Acidic Water tube Fig 9 Flexible outlet hose Acidic Water 1 4 White Bottom view of Ionize Bottom view of Ionize Place the water ionizer near the sink where the ionizer will be installed Rem...

Page 13: ...r faucet turn the lever to the OFF position The water will stop and the display panel will go dark indicating the ionizer is in standby mode NOTE Your ionizer will always remember the last setting use...

Page 14: ...nt of the faucet will show a blue Alkaline indicator and a number corresponding to the level selected TO CHANGE LEVELS OF ALKALINE WATER To select a different level depress the ALKALILNE button to mov...

Page 15: ...w if you open the port while water is flowing Unscrew the cap and remove Fig 26 The first time you remove it the cap may be tight Use a butter knife to work it free Take the basket apart from the cap...

Page 16: ...r cushion Push the filter down and into the housing compartment ensuring the opening at the top of the filter is seated properly into the fitting at the top of the housing Spin the filter to ensure a...

Page 17: ...out one hour after Your water bottle or receptacle is foul and needs cleaning Contamination mixes with alkaline water when filling your bottle Expired filter Clean your bottle or receptacle Try select...

Page 18: ...verall Dimensions Applicable Water inflow Pressure Applicable Water Tepmerature Unit Operation Type Unit Operation Means Electrolytic Device Water Purifying Device Electrolysis Method Alkaline Setting...

Reviews: