How to install your Ultra Delphi

Fig.8

Fig.9

Fig.10

Acidic Water (1/4”)

Inlet (1/4”)

Find the cold water supply
line and close the valve.

Disconnect the cold water hose from 
the line. Make sure it is the cold water 
hose and not hot because hot water 
will cause the unit to malfunction.

Connect the cold water line adapter to 
the cold water supply valve as shown.
As fittings vary you will need to find the 
right size adaptors at your local 
plumbing store.

Connect the plastic tubing 
as shown.

Separate the water line.

Connecting ionizing Unit to Cold Water Line

Connecting ionizing Unit to Faucet

1

2

4

5

6

3

1

2

4

5

3

See below for instructions on 
connecting the inlet and outlet hoses.

Installing the Inlet and Outlet Hoses for Countertop Use 

(Method 2 and 3)

Overview of Hose Connections 

(Method 2 and 3)

To connect water inlet hose, first remove the 1/4" plug from the cold 
water inlet fitting by sliding the collett release tool between the plug 
and the white collett to release the plug. With the collett tool in this 
position, the plug can be pulled out of the cold water inlet fitting. 
With the plug removed, simply press the 1/4" white water inlet tube in 
to the water inlet fitting making sure to press firmly to ensure a proper 
seal. (Fig.8)

To connect the Acidic Water outlet, follow instructions above using the 
Acidic outlet fitting and Acidic Water tube. (Fig.9)

Flexible outlet hose

Acidic Water (1/4”) White

(Bottom view of Ionize)

(Bottom view of Ionize)

Place the water ionizer near
the sink where the ionizer
will be installed.

Remove the aerator from the
faucet

Remove the compression nut from the 
diverter valve and thread the plastic 
supply tubing through it, making sure 
to keep the threads of the compression 
nut facing the diverter valve.

Attach the plastic supply tubing to the 
diverter by pressing it onto the compres-
sion nipple and securing the 
compression nut to the diverter valve.

Attach the diverter valve to the faucet 
using any included adapter rings 
necessary. Be sure to clean any exposed
threads and apply plumber’s tape to 
prevent leaks. 
If installing to a pull-out/spray stlye 
faucet, please contact your dealer for 
information on a specialty adapter that
may be required.

Optional Diverter

Method 2

Method 3

Acidic Water outlet

drains to sink.

Method 2 : Countertop Direct Plumbing

Method 3 : Countertop Connect to Faucet

CAUTION

Be sure the valves are all connected tightly to prevent leakage.

Be sure of where you want to install the ionizer as you will need 
to drill a hole through the sink top in order the thread the tube.

Be sure you connect the unit to cold water line.
Hot water can damage the unit.

This is a good time to double check and make sure all your 
fittings are tight and the tubing is secure in the fittings.

Check daily for any leaks during the first week after the 
installation and check for leaks occasionally there after.

Summary of Contents for AlkaViva ULTRA DELPHI

Page 1: ...This provides the electrodes with longevity built to last at least 20 years The titanium is coated with platinum for excellent yet durable conductivity Advanced Computerized PCB Hi Tech Microcomputer...

Page 2: ...r system in the world Your new UltraDelphi undersink ionizer is designed to provide you with many years of the cleanest healthiest and most functional water available Your new UltraDelphi undersink is...

Page 3: ...Use it while brushing your teeth Gargle with it and use it as a natural mouth wash The Acid Water has both antiseptic and antibacterial properties It also has an astringent effect and can be used for...

Page 4: ...failure to do so may result in electric shock or fire Do not wash your ionizer by immersion or by pouring water over the main body always unplug your ionizer while cleaning the casing Clean with damp...

Page 5: ...a doctor If the liquid gets in the eyes flush immediately and thoroughly with cool water call a doctor If spilled or dropped on your body wash if off immediately Make sure to keep the pH reagent liqui...

Page 6: ...of water you have selected on the machine FND Display Easily Identifies Your Selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum p...

Page 7: ...stainless steel Alkaline water outlet For optional counter top installation 1 2 3 4 Flow Control Knob 5 6 7 8 9 11 12 13 14 15 10 11 6 8 7 13 14 12 10 Main switch AC Power cord Filter cover 15 9 Calc...

Page 8: ...s selected a blue number 1 4 will indicate which level When Acid Water is selected an orange number 1 4 will indicate which level Filter life indicator Counts filter usage in a digital display Filter...

Page 9: ...ator If Alkaline Water is selected the BLUE indicator will be lit Acidic Water display indicator If Acidic Water is selected the ORANGE indicator will be lit Filtered Water display indicator It Filter...

Page 10: ...elease the hose from the fitting use the provide collet release tool to depress the spring loaded ring protruding from the end of the fitting while pulling the hose out Online videos are available sho...

Page 11: ...should not be able to pull the hose out Connect 5 16 Alkaline Water Hose to the large fitting attached to the corresponding faucet hose identified in Fig 7 above Pull firmly to check to connection you...

Page 12: ...itting and Acidic Water tube Fig 9 Flexible outlet hose Acidic Water 1 4 White Bottom view of Ionize Bottom view of Ionize Place the water ionizer near the sink where the ionizer will be installed Rem...

Page 13: ...r faucet turn the lever to the OFF position The water will stop and the display panel will go dark indicating the ionizer is in standby mode NOTE Your ionizer will always remember the last setting use...

Page 14: ...nt of the faucet will show a blue Alkaline indicator and a number corresponding to the level selected TO CHANGE LEVELS OF ALKALINE WATER To select a different level depress the ALKALILNE button to mov...

Page 15: ...w if you open the port while water is flowing Unscrew the cap and remove Fig 26 The first time you remove it the cap may be tight Use a butter knife to work it free Take the basket apart from the cap...

Page 16: ...r cushion Push the filter down and into the housing compartment ensuring the opening at the top of the filter is seated properly into the fitting at the top of the housing Spin the filter to ensure a...

Page 17: ...out one hour after Your water bottle or receptacle is foul and needs cleaning Contamination mixes with alkaline water when filling your bottle Expired filter Clean your bottle or receptacle Try select...

Page 18: ...verall Dimensions Applicable Water inflow Pressure Applicable Water Tepmerature Unit Operation Type Unit Operation Means Electrolytic Device Water Purifying Device Electrolysis Method Alkaline Setting...