How to Use

Installation method 1

Initial operation

To Select Filtered Water 

(Fig.14)

How to shut off the water flow from 
your ionizer

1

2

1

2

3

IMPORTANT! Complete all steps of installation method 1.(P 19) Make sure the main power switch is in the

OFF position on the back of the unit, and the unit is plugged into an electrical outlet.

Turn the power button to the "ON" position on the back of the 
ionizer. (Fig.11)
- The power button is ALWAYS left on.

Press the MODE button once. (Front panel of ionizer) (Fig.12)

TURN ON THE WATER
Turn on the water by opening the water supply valve under the sink.
Turn flow control knob on front of ionizer to ON position.
These will always remain in the ON or OPEN position.(Fig.13)

Fig.11

Fig.12

Fig.13

Fig.14

START WATER FLOW THROUGH YOUR IONIZER
- Turn on the "Lever" on the side of your faucet to 
   start the water flow.

With the water running through your faucet, press 
the "FILTERED" button.
The display panel will show a green symbol.
The Filtered water will come out of the top spout.

NOTE
The water may initally come out discolored(light to charcoal grey)
due to carbon particulate in the new filter. This is not harmful and
is typical of all carbon filters. Allow the water to flow for 2-3 minutes
in the "Filtered" mode and this will flush all the carbon dust.

Faucet Control Lever

Filtered Water

With the water running through your faucet, turn the lever to the 
OFF position.
The water will stop and the display panel will go dark indicating 
the ionizer is in standby mode.

NOTE
Your ionizer will always "remember" the last setting used.
If the previous selection was Alkaline level 2, when you start
flow through the ionizer next time you use the ionizer it will
automatically process at Alkaline level 2.

To select Alkaine Water 

(Fig.15)

To select Acidic Water 

(Fig.16)

1

2

1

2

START WATER FLOW THROUGH YOUR IONIZER
Depress the "ALKALINE" button to select the desired setting 
from 1~4.
The Alkaline Water will come out from the top spout. 
The display panel on the front of the faucet will show a blue 
Alkaline indicator and a number corresponding to the level 
selected.

TO CHANGE LEVELS OF ALKALINE WATER
To select a different level, depress the "ALKALILNE" button to 
move to next level until the desired setting level is achieved. 
The number will change accordingly.

START WATER FLOW THROUGH YOUR IONIZER.
Depress the "ACIDIC" button to select the desired from 1~4.
The Acidic Water will come out from the top spout. 
The display panel on the front of the faucet will show a red 
Acidic indicator and a number corresponding to the level selected.

TO CHANGE LEVELS OF ACIDIC WATER
To select a different level, depress the "ACIDIC" button to move 
to next level until the desired setting level is achieved.
The number will change accordingly

NOTE : Acidic Water is for external use only. DO NOT DRINK.

Faucet Control Lever

Fig.15

Alkaline Water

Acidic Water

Faucet Control Lever

Fig.16

Alkaline Water

Acidic Water

Summary of Contents for AlkaViva ULTRA DELPHI

Page 1: ...This provides the electrodes with longevity built to last at least 20 years The titanium is coated with platinum for excellent yet durable conductivity Advanced Computerized PCB Hi Tech Microcomputer...

Page 2: ...r system in the world Your new UltraDelphi undersink ionizer is designed to provide you with many years of the cleanest healthiest and most functional water available Your new UltraDelphi undersink is...

Page 3: ...Use it while brushing your teeth Gargle with it and use it as a natural mouth wash The Acid Water has both antiseptic and antibacterial properties It also has an astringent effect and can be used for...

Page 4: ...failure to do so may result in electric shock or fire Do not wash your ionizer by immersion or by pouring water over the main body always unplug your ionizer while cleaning the casing Clean with damp...

Page 5: ...a doctor If the liquid gets in the eyes flush immediately and thoroughly with cool water call a doctor If spilled or dropped on your body wash if off immediately Make sure to keep the pH reagent liqui...

Page 6: ...of water you have selected on the machine FND Display Easily Identifies Your Selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum p...

Page 7: ...stainless steel Alkaline water outlet For optional counter top installation 1 2 3 4 Flow Control Knob 5 6 7 8 9 11 12 13 14 15 10 11 6 8 7 13 14 12 10 Main switch AC Power cord Filter cover 15 9 Calc...

Page 8: ...s selected a blue number 1 4 will indicate which level When Acid Water is selected an orange number 1 4 will indicate which level Filter life indicator Counts filter usage in a digital display Filter...

Page 9: ...ator If Alkaline Water is selected the BLUE indicator will be lit Acidic Water display indicator If Acidic Water is selected the ORANGE indicator will be lit Filtered Water display indicator It Filter...

Page 10: ...elease the hose from the fitting use the provide collet release tool to depress the spring loaded ring protruding from the end of the fitting while pulling the hose out Online videos are available sho...

Page 11: ...should not be able to pull the hose out Connect 5 16 Alkaline Water Hose to the large fitting attached to the corresponding faucet hose identified in Fig 7 above Pull firmly to check to connection you...

Page 12: ...itting and Acidic Water tube Fig 9 Flexible outlet hose Acidic Water 1 4 White Bottom view of Ionize Bottom view of Ionize Place the water ionizer near the sink where the ionizer will be installed Rem...

Page 13: ...r faucet turn the lever to the OFF position The water will stop and the display panel will go dark indicating the ionizer is in standby mode NOTE Your ionizer will always remember the last setting use...

Page 14: ...nt of the faucet will show a blue Alkaline indicator and a number corresponding to the level selected TO CHANGE LEVELS OF ALKALINE WATER To select a different level depress the ALKALILNE button to mov...

Page 15: ...w if you open the port while water is flowing Unscrew the cap and remove Fig 26 The first time you remove it the cap may be tight Use a butter knife to work it free Take the basket apart from the cap...

Page 16: ...r cushion Push the filter down and into the housing compartment ensuring the opening at the top of the filter is seated properly into the fitting at the top of the housing Spin the filter to ensure a...

Page 17: ...out one hour after Your water bottle or receptacle is foul and needs cleaning Contamination mixes with alkaline water when filling your bottle Expired filter Clean your bottle or receptacle Try select...

Page 18: ...verall Dimensions Applicable Water inflow Pressure Applicable Water Tepmerature Unit Operation Type Unit Operation Means Electrolytic Device Water Purifying Device Electrolysis Method Alkaline Setting...

Reviews:

Related manuals for AlkaViva ULTRA DELPHI