background image

Operating instructions 

(EN)

Additional faucet for ECAIA ionizer S

Additional operating instructions to be used in combination with

User manual for the ECAIA ionizer S

Distributed worldwide by:
SANUS

LIFE

 

INTERNATIONAL GmbH 

Luigi Negrelli 13/C, 39100 Bolzano (I)
Phone: +39 0471 979998 

www.sanuslife.com - [email protected]

   

 

      ionizer S faucet

Version 21.06.30

ACID

ALK

PU

②            ①

Filter

EN  

 

Operating instructions

Long version

Summary of Contents for ECAIA S

Page 1: ...be used in combination with User manual for the ECAIA ionizer S Distributed worldwide by SANUSLIFEINTERNATIONAL GmbH Luigi Negrelli 13 C 39100 Bolzano I Phone 39 0471 979998 www sanuslife com info sanuslife com ionizer S faucet Version 21 06 30 ACID ALK PU Filter EN Operating instructions Long version ...

Page 2: ...2 1 2 3 4 5 6 7 1 0 13 8 1 1 1 4 9 1 2 1 5 1 4 12 x 1 4 2 x 3x8 mm 2 x 4x16 mm 4 x 5 16 5 16 D D5 D3 D2 D6 D1 D4 C Scope of delivery ECAIA ionizer S faucet D ECAIA ionizer S faucet Display ...

Page 3: ...3 Maximum distance between faucet and ionizer 1 5 m 5 16 1 4 1 4 1 4 5 16 5 16 13 C B C C C C 5 16 1 4 1 4 1 4 Ø 35 mm E Installation diagram Point 4 1 page 6 F Installation diagram Point 4 2 page 7 ...

Page 4: ...ECAIA ionizer S 9 4 4 Reprogramming the ECAIA ionizer S control to ECAIA ionizer S 11 4 5 Operation of ECAIA ionizer S faucet 12 The following items are included in the scope of delivery see Figure C on page 2 2 way water tap ECAIA ionizer S faucet Seal for faucet Reinforcing plate Fixing nut Quick release fastener 1 x adapter 5 16 to 1 4 1 x angle adapter 90 5 16 to 5 16 1 x angle adapter 90 1 4 ...

Page 5: ...l purify PU filtered water flows out of the upper and lower outlets E F ionization is deactivated Display indicates the selected ionization level AL1 alkaline level 1 AL2 alkaline level 2 AL3 alkaline level 3 AL4 alkaline level 4 AL5 alkaline level 5 AC1 acidic level 1 AC2 acidic level 2 PU PURIFY Filter indicator depending on which filter 1 or 2 lights up the flow rate 0 to 999 is shown on the di...

Page 6: ...tween CAUTION When assembling please make sure the connection pins on the T piece do not bend sideways This may cause a micro crack which can even lead to breakage due to the constant water pressure 2 Verbinden Sie den Trinkwasser Zulauf schlauch A 6 mit der Schnellverschluss Öffnung am T Stück A 10 und fixieren Sie den Sicherheitsstift 1 4 C 6 3 Connect the other end of the tap water supply hose ...

Page 7: ...necessary If the flow becomes slower after a while the filter A 7 and or the water pressure reducing valve C 13 may be dirty and may need to be cleaned or replaced 4 2 Installation of the additional ECAIA ionizer S faucet Compare table F page 3 In order to avoid damaging the fixtures and fittings the hoses should be connect ed by a professional 1 Connect the 5 16 outlet hose for al kaline water C ...

Page 8: ...trol has been reprogrammed see point 4 3 to the ECAIA ioniz er S 5 16 1 4 5 16 5 Attach the 5 16 outlet adapter for alkaline water C 7 to the upper water outlet B 5 on the device by screwing it in until it stops the flexible outlet hose for alkaline water A 2 is not required Then connect the 5 16 quick re lease angle adapter C 5 to the 5 16 outlet adapter for alkaline water C 7 After that connect ...

Page 9: ...the cord band C 9 To use the ECAIA ionizer S as an under sink model in combination with the ECAIA ion izer S faucet the control unit must first be upgraded to ECAIA ionizer S Proceed as follows 1 Plug the power cable of the ECAIA Ionizer S into the socket The device requires 230V US model 120V 2 Press and hold on the ECAIA ionizer S the button combination alkaline level 5 B 24 and PURIFY B 26 at t...

Page 10: ...play B 2 switches off This saves the setting 5 Unplug the power cable of the ECAIA ionizer S from the socket so that the device no longer receives power 6 Connect the control cable D A to the connector provided under the connection cover B 7 on the rear of the ECAIA ionizer S 7 Plug the power cable of the ECAIA Ionizer S into the socket The ECAIA ionizer S is now only be operable via the buttons o...

Page 11: ...d the Acidic levels ACID D D3 but ton until F 0 appears on the display 3 On the ECAIA ionizer S faucet press and hold the Power D D1 and Alkaline lev els ALK D D2 buttons at the same time until the display switches off This saves the setting 4 Unplug the power cable of the ECAIA ionizer S from the socket so that the device is no longer connected to the electricity supply 5 Carefully disconnect the...

Page 12: ...or acidic levels D D3 allows you to switch between acidic levels 1 and 2 To do this read the instructions under point 1 12 De scription of the buttons in the full user manual long version for the ECAIA ionizer S By pressing and holding the ACID button D D3 for more than 5 seconds you can set the ionization output for the selected acid level To do this read the instructions under point 1 14 Setting...

Page 13: ...13 ...

Page 14: ...dditional faucet for ECAIA ionizer S Distributed worldwide by SANUSLIFE INTERNATIONAL GmbH Luigi Negrelli 13 C 39100 Bolzano I Phone 39 0471 979998 www sanuslife com info sanuslife com ACID ALK PU Filter ...

Reviews: