EMC INDUSTRIAL GROUP LTD
Keys
MW61A_IM_ALL_SV6.09d_en
46/47
print total
Press this key to print the totalised weight.
reset peak weight
Press this key to reset the peak weight.
reset total weight
Press this key to reset the totalised weight.
acquire zero
Press this key to zero the weight display.
totalise
Press this key to add the currently displayed weight to the totaliser.
Settings
set tare weight
Press this key to display the TARE WEIGHT setting. Use the keypad to set the tare weight.
set setpoint
Press this key to display the SETPOINT 1 (high limit) setting. Use the keypad to set the setpoint.
Alarm menu
An alarm is indicated by a flashing alarm icon. An alarm number will flash in the display while a fault is
active or until it is acknowledged.
Press the ALARM key to see the alarm menu and acknowledge the alarms. The menu shows a list of the
previous alarms.
For details on an alarm in the list, use the UP, DOWN and ENTER keys, or key in the number next to
the alarm.
Press BACK to exit the alarm menu, or press 6 to clear the alarms and exit the menu.