EMC INDUSTRIAL GROUP LTD
Communications & Display
MW61A_IM_ALL_SV6.09d_en
37/47
Value
Display
Description
1
kg
hide units
2
hide net/gross icon
4
hide tare icon
8
hide zero icon
16
hide zero band icon
32
hide motion icon
64
HL
hide setpoint 1 icons
128
LL
hide setpoint 2 icons
256
GROSS
hide gross weight bar graph
1024
do not display secondary line
0
-
nothing displayed
2048
N1
(
654321
)
display running total
Q25654 display select sourceA
8600, g14
peak weight=8240
Q25655 display select sourceB
8602, g14
total weight=8730
The above two settings allow up to two additional settings to be added to the items displayed in the
bottom line of the display. These items are selected during normal use with the DISPLAY key.
Q25656 menu sourceA
8604, g14
0
Q25657 menu sourceB
8606, g14
0
Q25658 menu sourceC
8594, g14
0
The above three settings allow up to three additional settings to be added to the operator menu.
These items will appear in the menu shown when the MENU key is pressed during normal operation.
Q25659 display select options
8678, g14
0
Controls the select line at the bottom of the display.
Add up the numbers in the following table to change the display as described.
Select line
Value
Description
1
permanently hide the whole line
2
hide the logo
Softkey customisation
These settings set the functions of each of the soft keys A, B, C, D and E.
Q25661 key A function & lock
8690, g4
9
Q25662 key B function & lock
8692, g4
0
Q25663 key C function & lock
8694, g4
3
Q25664 key D function & lock
8696, g4
2
Q25665 key E function & lock
8698, g4
1
Signal customisation
These settings allow the names and units of any signal to be changed.
Signal 1
Q256711 signal 1 source
18000
Q256712 signal 1 name
4000
Q256713 signal 1 type
18010
Signal 2
Q256721 signal 2 source
18002
Q256722 signal 2 name
4100
Q256723 signal 2 type
18012