EDS ENVIRONMENTAL SENSOR IDS
ID
Features
EDS1064
Temperature
EDS1065
Temperature & humidity
EDS1066
Temperature & barometric pressure
EDS1067
Temperature & light
EDS1068
Temperature, humidity, barometric pressure, & light
EDS2030
Dual RTD Input with high power radio
EDS2033
Dual Analog Input with high power radio
EDS2040
Temperature, humidity, external probe support, memory buffer, & high power radio
EDS2041
Temperature, humidity, external probe support, 2K memory buffer, high power radio, & buffer only mode
EDS2042
Up to 3 waterproof external temperature probes, 2K memory buffer, high power radio, & buffer only mode
EDS REPEATER DEVICE IDS
ID
Features
EDS2101
MeshNet Repeater with high power radio
SPECIFICATIONS
PARAMETER
MIN
TYP
MAX
UNITS
Operating Temperature Range
-40
-
85
°C
Accuracy (-200 to 800) with Input at 21°C
-0.1
-
0.1
°C
Battery Supply Voltage (battery in series)
2.2
-
3.1
Volts
Inline Power Supply
4
-
16
Volts
Enclosure Dimensions (L x W x H)
100
100
40
Mm
Notes:
1. The battery voltage varies depending on how much current is flowing. When the sensor is sleeping, the voltage is
higher than when it is awake. The reading is taken when the sensor is awake.