Embedded Data Systems MN-RTD4W-H Manual Download Page 7

 

© 2020 Embedded Data Systems, LLC.; 2019 Fortune Drive; Lawrenceburg, KY 40342; Phone/Fax 502-859-5490     7 / 10 

EN-USERMAN MN-RTD4W-H V1.0  10.09.2020 

PROGRAMMABLE/WRITEABLE PARAMETER SUMMARY 

Parameter 

Description  

Limitations 

UserName 

User friendly name for the sensor  

29 characters 0-9, A-z, and 

special characters (space and “.”) 

SensorReadPeriod 

Selects the transmission rate (see selectable transmission 

rates on page 4)  

11 transmission rate options 

ResetMessageCounters 

Resets MessageAttempts, MessagePacketRetries, and 

MessageFailures to 0. 

 

InputSend 

Enabling (set to 1) configures sensor to transmit when 

scheduled and when the input state changes.  

0 to 1 

FactoryReset 

Resets all programmable settings except UserName and 

Network Key. 

Only occurs if ReadCounter is 

below 20. 

Linked 

Writing a Controller’s NetKey to the Linked Parameter has 

it join the Controller’s network.  The unlinked NetKey is 

FFFFFFFF. 

Must write an 8 digit Hexadecimal 

number (0-9 & A-F).    

CalibrationKey 

Writing the appropriate command will calibrate to RTD 
Input to 100 Ohms.  Details available in the calibration 

section. 

 

 
 

BATTERY LIFE 

The RTD Input spends most of its time in sleep mode; it wakes up to take readings, send data and see if any packets are 
in the queue to be received. Battery life can be maximized by reading/sending the sensor data as infrequently as possible. 
Battery life is highly variable on a number of parameters.  

1.  How often data is read/sent. 
2.  Extreme temperatures reduce the useful life of the battery.  
3.  If the sensor is sending data through a repeater, battery life will be reduced because the sensor has to wait longer 

for the acknowledgment. 

4.  If the sensor has to reconnect to the controller frequently, battery life will be reduced. This happens when the 

signal is low or there is interference. 

5.  Channel hopping 
6.  The battery chemistry will affect the performance.  Lithium batteries will provide substantially better performance 

especially in cold environments.   

 
Expected battery life in normal conditions at a 1 minute transmission rate is 2+ years.     
 

INLINE POWER (Optional with MOQ) 

A RTD Input with inline power and battery backup is available for special order.  A power supply capable of providing 4 to 
16VDC with a right angle 2.5mm barrel connector is suggested.  The battery backup is not charged by the presence of 
inline power. 
 

RTD INPUT CALIBRATION 

Each input is factory calibrated to ±0.01% accuracy at 21°C.  The Callendar-Van Dusen equation and calibration 
performed on each reading.  It has an accuracy of ± 0.1° across probes temperature (with MeshNet RTD Input at 21°C

6

). 

 

                                                 

6

 The MeshNet RTD Input may be recalibrated at temperatures significantly different than 21°C.  Contact 

[email protected]

 for more details. 

     
 

Summary of Contents for MN-RTD4W-H

Page 1: ...or s transmission range RTD fault detection and screw down terminals Together these features offer an efficient and flexible system for monitoring wide temperature ranges from 200 to 800 C RTD dependent the temperature at multiple indoor and outdoor locations Part Numbers Description MOQ MN RTD4W H Two 4 Wire RTD Connections with Battery Power 1 MN RTD4W H PLUG Two 4 Wire RTD Connections Plugin Po...

Page 2: ...will flash rapidly indicating that the sensor is now in an active state 8 Close the enclosure making sure that the screw down terminal is on the opposite side of the cable grommet to improve wireless performance by keeping the cables away from the wireless antenna 9 Lightly pull the cable to remove excess cabling from within the enclosure 10 Take the 4 screws included in your hardware bag and secu...

Page 3: ...er higher numbers equate to stronger signals Due to hardware limitations the highest number that can be displayed is 34 dBm However the actual signal strength may be much higher DeviceRSSI This indicates the strength of the radio signal at the sensor Due to hardware limitations the highest number that can be displayed is 34 dBm however the actual signal strength may be much higher Address This is ...

Page 4: ...dicates the oldest unsent buffered packet in the buffer When the BufferHeadPointer and BufferTailPointer are the same the buffer is empty RTD1ValueCalibration RTD2ValueCalibration It contains the factory calibration for the input channels Factory Reset Web soft reset Writing anything to the FactoryReset location will return all parameters except for the UserName and the Network Key to factory defa...

Page 5: ...r increments until the counter is reset MessagePacketRetries The number of times wireless packets had to be resent due to no acknowledgment being received The maximum is 65535 after which it no longer increments until the counter is reset MessageFailures When no acknowledgment is received the packet is resent After 4 retries the message has failed The counter increments when a failure has occurred...

Page 6: ... EDS RTD Sensor UserName owd_EDS2030_Tag owd_EDS2030_Data Description RTD Sensor with high power transceiver and power management Name EDS2030 Name EUI 801F12FFFECB7C0C EUI ControllerRSSI Units dBm 41 ControllerRSSI Address 1 Address Repeater 0 Repeater TimeStamp 2020 05 05 12 19 31 TimeStamp RTD1Temperature 250 000 RTD1Temperature RTD1Ohms 0 000 RTD1Ohms RTD1Fault 1 RTD1Fault RTD1CalibrationValue...

Page 7: ...n be maximized by reading sending the sensor data as infrequently as possible Battery life is highly variable on a number of parameters 1 How often data is read sent 2 Extreme temperatures reduce the useful life of the battery 3 If the sensor is sending data through a repeater battery life will be reduced because the sensor has to wait longer for the acknowledgment 4 If the sensor has to reconnect...

Page 8: ...ces When the name and password is requested enter admin for the name and eds for the password A page similar to below will appear 5 Insert AA batteries into sensor Once this is done the sensor will appear 7 in the Unlinked Devices section 6 Click the unlinked sensor A window will pop up confirming you want to link the sensor Click OK The sensor will move to the Linked Devices section upon its next...

Page 9: ...Temperature humidity external probe support 2K memory buffer high power radio buffer only mode EDS2042 Up to 3 waterproof external temperature probes 2K memory buffer high power radio buffer only mode EDS REPEATER DEVICE IDS ID Features EDS2101 MeshNet Repeater with high power radio SPECIFICATIONS PARAMETER MIN TYP MAX UNITS Operating Temperature Range 40 85 C Accuracy 200 to 800 with Input at 21 ...

Page 10: ... COMPLIANCE STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada EUROPEAN COMMUNITY EC DIRECTIVES CONFORMITY APPLICATION OF COUNCIL DIRECTIVE 2004 108 EC Standard to which Conformity is Declared EN 61326 1 2006 Emmissions EN 61326 2 3 2006 Immunity EN 61000 3 2 2006 A1 2009 A2 2009 Harmonics EN 6100...

Reviews: