1. Use ONLY ICF system components; Locking Ring unit doing assembly, metal-reinforced seal. Non-tighten locking 

ring  components  may  fail  in  use  and  cause  explosive  component  separation.  Verify  that  upper  and  lower  filter 

bodies are properly secured with the filter body locking ring unit. Make sure hand tightening enough the locking 

Ring  enough  to  the  filter  upper  and  bottom  body.  Verify  that  the  filter  manual  air  release  valve  is  in  the  LOCK 

position, and no filter components are missing, damaged, or not genuine ICF filter components. 

6. Install the plumbing from the filter to the pool (return to the pool)

7. Do not locate pump controls over or near the filter.

8. Verify water discharge from the manual air Relief valve is directed away from electrical devices.

3.1 BEFORE STARTING THE PUMP 

P5   STARTING THE PUMP AND FILTER SYSTEM

STARTING THE PUMP AND FILTER SYSTEM    P6

Pool and spa circulation systems operate under high pressure. When any 

part  of  the  circulating  system  (i.e.  lock  ring,  pump,  filter,  valves,  etc.)  is 

ser viced, air can enter the system and become pressurized. Filter tank Lid 

and  pre-filter  cover  must  be  properly  secured  to  prevent  violent 

separation. Place pre-filter / filter air relief valve in the open position and 

wait for all pressure in the system to be relieved before remove the lib to 

access the basket for cleaning.

3.2 STARTING PUMP

Filtration starts as soon as the flow is steady through the filter. 

As  the  filter  removes  dir t  from  the  pool  water,  the 

accumulated  dirt  causes  a  resistance  to  flow.  As  a  result,  the 

gauge pressure will rise and the flow will decrease. When the 

pressure rises to 30 psi (200 kPa) above the starting pressure, 

or  when  the  flow  decreases  below  the  desired  rate,  clean  or 

replace the filter cartridge elements. 

Once  your  filter  is  running  and  there  is  a  pressure  reading, 

turn  the  outer  dial  “START”  arrow  marker  to  the  pressure 

gauge  pointer  position.  When  the  pressure  rises  to  or  above 

the “CLEAN FILTER” marker, it is time to clean or replace your 

filter cartridge elements.

By  recording  the  initial  starting  pressure  (with  clean  filter 

elements)  a  determination  can  be  made  when  the  filter 

cartridge  elements  should  be  replaced  rather  than  cleaned. 

After  the  filter  elements  have  been  cleaned  and  reinstalled  if 

the  starting  pressure  is  higher  than  25  PSI  above  the  starting  pressure  with  the  new  filter  cartridge  elements, 

the filter cartridge elements should be replaced the next time the gauge arrow reaches the red zone.

A

REQUIRED CLEARANCE

“B” side

“C” above 

IN

32.6

36

40.7

CM

82.7

91.2

103.4

IN

18.3

18.3

18.3

CM

46.4

46.4

46.4

IN

11.8

11.8

11.8

CM

30

30

30

ICF 100

ICF 150

ICF 200

MODEL

3. STARTING THE PUMP AND FILTER SYSTEM

2. Close filter drain. Note: Filter plug requires an O ring seal. 

Sealing O ring

Drain Plug

Figure 2

3.Open all system valves to allow water from the pool to the filtration system and from the filter to return to the 

pool.

4.Place the manual air release valve in an OPEN position. 

Stand clear of pump during start-up

4.When starting the system pump, do not stand over or near the filter. If water leakage appears at the filter tank 

clamp, immediately turn off all system circulation pumps and all electrical power. Do not return to the filter until 

all  water  leakage  has  stopped.  Reassemble  the  clamp  system  per  the  instructions  of  the  previous  page  in  this 

owner ’s manual to stop the leak .

5.Return  to  the  filter  and  only  CLOSE  the  manual  air  relief  valve  if  a  steady  stream  of  water  escapes  from  the 

valve and not air or an air-water mix.

3.3 OPERATION

Drain plug

Outlet

Bottom base

Inlet

Locking Ring

Upper body

Release valve

Pressure gauge

Latch

A

C

B

Figure 4

Figure 1

Figure 3

Air release valve
in open position

Release the Latch by hand for
unlocking First then turning to Ring

Pressure gage

Release valve

Locking/unlocking
direction

Summary of Contents for ICF 100

Page 1: ...USER MANUAL STRIVE FOR CLEAR WATER www emauxgroup com SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Manual EMAUX WATER TECHNOLOGY CO LTD Models ICF 100 ICF 150 ICF 200 EMFI22021501 ...

Page 2: ...repositioning valve s and before beginning the assembly disassembly or any other service of the circulating system 1 Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing open the manual air release valve Wait until all pressure is relieved 3 Whenever installing the filter closure follow the filter closure warnings exactly 4 On...

Page 3: ...exceed the maximum operating pressure of the system components Exceeding these limits could result in a component failing under pressure This instantaneous release of energy can cause the closure to separate and could cause severe personal injury or death if they were to strike a person This product should be installed and serviced only by a qualified pool professional 1 The filter system should b...

Page 4: ...re reading turn the outer dial START arrow marker to the pressure gauge pointer position When the pressure rises to or above the CLEAN FILTER marker it is time to clean or replace your filter cartridge elements By recording the initial starting pressure with clean filter elements a determination can be made when the filter cartridge elements should be replaced rather than cleaned After the filter ...

Page 5: ...en hose After hosing the cartridge for best results carefully brush the pleated surface to remove fine particles Do not pressure wash as it can damage the filter element You may find some debris on the cartridge pleats which may not have been removed with hosing 4 4 FILTER REASSEMBLY INSTRUCTIONS 4 4 1 RE INSTALLING CARTRIDGES 1 Remove filter tank sealing O Ring 2 With a clean cloth wipe the lower...

Page 6: ...0 to 400 ppm 0 2 ppm Maximum 1 0 to 3 0 ppm 60 to 80 ppm 4 5 REMOVING THE MANUAL AIR RELEASES VALVE The filter comes with a preinstalled manual air relief valve Servicing the Manual Air Release Valve MAR should be carried out by pool professionals only by carefully following the instructions 1 Turn off all system circulation pumps and all electric power on the equipment pad 2 Set all system valves...

Page 7: ...tack or g as a result of service by anyone other than Emaux authorized reseller or authorized agent EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY EMAUX MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMAUX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE...