background image

P7    MAINTAINING YOUR FILTER 

MAINTAINING YOUR FILTER     P8

1.Turn off all system circulation pumps and all-electric power on the equipment pad. 

2.Set all system valves in a position to prevent water flow to the filter.

3.The manual air release valve must be placed in the OPEN position. 

4.Remove the filter drain plug and drain water from the filter.

5.Holding locking Ring Unit of the filter clamp carefully as, lifting through top filter body. Do not drop the locking 

ring  unit  during  removal,  because  the  locking  ring  unit  could  be  damaged.  Do  not  strike  the  locking  Ring  unit 

with metal tools as they can damage the clamp.

6.Lift off upper filter body. Do not use the pressure gauge to lift the upper filter body.

4.1 FILTER DISASSEMBLY INSTRUCTIONS

1.Flush and drain any dirt or debris from the bottom of the lower filter body.

2.Flush any dirt or debris from the upper filter body and from around the manual air release area.

3.Carefully replace the cartridges over the hubs on the bottom manifold.

4.Place top filter body securely on top of cartridges.

4. MAINTAINING YOUR FILTER 

4.2 REMOVING CARTRIDGES

1.Remove the filter cartridge elements by using a slight rocking motion and lifting.

2.Clean filter cartridge elements.

4.3 CLEANING CARTRIDGES

The  Cartridge  filter  element  can  be  cleaned  by  washing  inside  and  outside  with  a  garden  hose.  After  hosing  the 

cartridge, for best results, carefully brush the pleated surface to remove fine particles. Do not pressure wash as it 

can damage the filter element.

You may find some debris on the cartridge pleats, which may not have been removed with hosing

4.4 FILTER REASSEMBLY INSTRUCTIONS

4.4.1 RE-INSTALLING CARTRIDGES

1.Remove filter tank sealing O Ring.

2.With a clean cloth, wipe the lower filter body seal surface and clean seal of all dirt and debris.  Do not use a 

solvent.

3.With a clean cloth wipe the upper filter body seal surface.

4.4.2 CLEAN SEAL RING AND SEAL SURFACE

4.4.3 CLEAN SEAL RING AND SEAL SURFACE

1.Place the Sealing O Ring on the lower filter body.  

2.Place the upper filter body on Sealing O Ring and lower filter base in a position that allows all operation and 

safety labels to be visible and the upper filter body to be centered on the lower filter base. Press down firmly 

and evenly on the upper filter body to seat the seal. 

NOTE: If the O-ring is damaged it must be replaced

3.Hold the Locking Ring latch unit and turn it to closed direction for locking the Ring unit in tight of Upper and 

bottom filter bodies until the latch unit into locking position and operation labels on the filter bodies. 

4.Checking  and  making  sure  the  Locking  Ring,  Upper  filter  body,  and  bottom  base  filter  body  are  in  tight 

condition.

DO NOT HIT OR STRIKE CLAMP WITH HAMMER OR METAL TOOLS.

5.Follow Operation Instructions for “Starting the Pump and Filter System” .

Figure 5

Cartridge elements 

Sealing O ring 

Bottom base

Summary of Contents for ICF 100

Page 1: ...USER MANUAL STRIVE FOR CLEAR WATER www emauxgroup com SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Manual EMAUX WATER TECHNOLOGY CO LTD Models ICF 100 ICF 150 ICF 200 EMFI22021501 ...

Page 2: ...repositioning valve s and before beginning the assembly disassembly or any other service of the circulating system 1 Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing open the manual air release valve Wait until all pressure is relieved 3 Whenever installing the filter closure follow the filter closure warnings exactly 4 On...

Page 3: ...exceed the maximum operating pressure of the system components Exceeding these limits could result in a component failing under pressure This instantaneous release of energy can cause the closure to separate and could cause severe personal injury or death if they were to strike a person This product should be installed and serviced only by a qualified pool professional 1 The filter system should b...

Page 4: ...re reading turn the outer dial START arrow marker to the pressure gauge pointer position When the pressure rises to or above the CLEAN FILTER marker it is time to clean or replace your filter cartridge elements By recording the initial starting pressure with clean filter elements a determination can be made when the filter cartridge elements should be replaced rather than cleaned After the filter ...

Page 5: ...en hose After hosing the cartridge for best results carefully brush the pleated surface to remove fine particles Do not pressure wash as it can damage the filter element You may find some debris on the cartridge pleats which may not have been removed with hosing 4 4 FILTER REASSEMBLY INSTRUCTIONS 4 4 1 RE INSTALLING CARTRIDGES 1 Remove filter tank sealing O Ring 2 With a clean cloth wipe the lower...

Page 6: ...0 to 400 ppm 0 2 ppm Maximum 1 0 to 3 0 ppm 60 to 80 ppm 4 5 REMOVING THE MANUAL AIR RELEASES VALVE The filter comes with a preinstalled manual air relief valve Servicing the Manual Air Release Valve MAR should be carried out by pool professionals only by carefully following the instructions 1 Turn off all system circulation pumps and all electric power on the equipment pad 2 Set all system valves...

Page 7: ...tack or g as a result of service by anyone other than Emaux authorized reseller or authorized agent EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY EMAUX MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMAUX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE...