P3 OVERVIEW
INSTALLATION P4
1. OVERVIEW
ICF series cartridge filter combines superior water filtration with ease of operation and corrosion-free
construction. With filtration ratings of 6,000~7,200 gallons (22,710 ~ 27,250 liters) per hour, they are designed for
continuous or intermittent operation, for installation above or below the pool waterline, for fresh or saltwater
swimming pools or spas. ICF series filters utilize multiple reusable, reinforced polyester filter cartridge elements to
provide a high degree of water clarity and long filter cycles with minimum care.
Do not operate the filter until you have read and understand clearly all the operating
instructions and warning messages for all equipment that is a part of the pool circulating
system. The following instructions are intended as a guide for initially operating the filter in a
general pool installation. Failure to follow all operating instructions and warning messages can
result in property damage or severe personal injur y or death.
To reduce the risk of injur y, do not permit children to use this product unless they are closely
super vised at all times.
Due to the potential risk that can be involved it is recommended that the
pressure test be kept to the minimum time required by the local code. Do
not allow people to work around the system when the circulation system is
under pressure test. Post appropriate warning signs and establish a barrier
around the pressurized equipment. If the equipment is located in an
equipment room, lock the door and post a warning sign.
Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is pressurized.
These actions can cause the closure to separate and could cause severe personal injur y or death if they were to
strike a person.
N e ve r e xc e e d t h e m a x i m u m o p e r a t i n g p re s s u re of t h e s y s te m
components. Exceeding these limits could result in a component failing
under pressure. This instantaneous release of energy can cause the
closure to separate and could cause severe personal injur y or death if they
were to strike a person.
This product should be installed and ser viced only by a qualified pool professional.
1.The filter system should be installed on a level concrete slab or another rigid base. Select a well-drained and
vented area, one that does not flood when it rains. Position the filter so that the piping connections and
winter drain are convenient and accessible for operation, ser vice, maintenance, and winterizing.
2.Position filter body such that all operation and safety labels are visible.
3.Position filter so the filter will drain by gravity.
4.If practical, place the pump and filter in the shade to shield it from continuous, direct heat from the sun.
5.Connect the pool suction plumbing between the skimmer, pool outlet (from the pool), and the pump.
2. INSTALLATION
HYPERTHERMIA
SPA water temperature excess 38°C (104°F) may be injurious to health.
Measure water temperature before entering SPA.were to strike a person.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal
body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase
in the internal temperature of the body.
1.1 PRODUCT INFORMATION
Model
EFFECTIVE FITRATION
AREA
ICF 100
ICF 150
ICF 200
CODE
DESIGN FLOW RATE
Residential Commercial
100
150
200
FT²
9.29
13.94
18.58
M²
100
120
120
GPM
379
455
455
LPM
1.2 DIMENSIONS
ICF 100
Outer dimension diagram
ICF 150
ICF 200
CM
53.05
23.00
46.40
8.20
IN
20.9
9.05
18.30
3.20
CM
53.05
31.50
46.40
8.20
IN
20.90
12.40
18.30
3.20
CM
53.05
43.80
46.40
8.20
IN
20.90
17.24
18.30
3.20
A
B
C
D
9140401
9140402
9140403
A
B
D
C
[ Filter rate for residential use based on 1GPM/ft². Recommend Flow Rate for 2” piping is 90
x 150 GPM ]
≤ ≤