emaux ICF 100 Installation And Operation Manual Download Page 3

P3    OVERVIEW

INSTALLATION     P4

1. OVERVIEW

ICF  series  cartridge  filter  combines  superior  water  filtration  with  ease  of  operation  and  corrosion-free 

construction. With filtration ratings of 6,000~7,200 gallons (22,710 ~ 27,250 liters) per hour, they are designed for 

continuous  or  intermittent  operation,  for  installation  above  or  below  the  pool  waterline,  for  fresh  or  saltwater 

swimming pools or spas. ICF series filters utilize multiple reusable, reinforced polyester filter cartridge elements to 

provide a high degree of water clarity and long filter cycles with minimum care.

Do  not  operate  the  filter  until  you  have  read  and  understand  clearly  all  the  operating 

instructions  and  warning  messages  for  all  equipment  that  is  a  part  of  the  pool  circulating 

system. The following instructions are intended as a guide for initially operating the filter in a 

general pool installation. Failure to follow all operating instructions and warning messages can 

result in property damage or severe personal injur y or death.

To reduce the risk of injur y, do not permit children to use this product unless they are closely 

super vised at all times.

Due to the potential risk that can be involved it is recommended that the 

pressure test be kept to the minimum time required by the local code. Do 

not allow people to work around the system when the circulation system is 

under pressure test. Post appropriate warning signs and establish a barrier 

around  the  pressurized  equipment.  If  the  equipment  is  located  in  an 

equipment room, lock the door and post a warning sign.

Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is pressurized. 

These  actions  can  cause  the  closure  to  separate  and  could  cause  severe  personal  injur y  or  death  if  they  were  to 

strike a person.

N e ve r  e xc e e d  t h e  m a x i m u m  o p e r a t i n g  p re s s u re  of  t h e  s y s te m 

components.  Exceeding  these  limits  could  result  in  a  component  failing 

under  pressure.  This  instantaneous  release  of  energy  can  cause  the 

closure to separate and could cause severe personal injur y or death if they 

were to strike a person.

This product should be installed and ser viced only by a qualified pool professional.   

1.The filter system should be installed on a level concrete slab or another rigid base. Select a well-drained and  

vented  area,  one  that  does  not  flood  when  it  rains.  Position  the  filter  so  that  the  piping  connections  and 

winter drain are convenient and accessible for operation, ser vice, maintenance, and winterizing. 

2.Position filter body such that all operation and safety labels are visible.

3.Position filter so the filter will drain by gravity.

4.If practical, place the pump and filter in the shade to shield it from continuous, direct heat from the sun.

5.Connect the pool suction plumbing between the skimmer, pool outlet (from the pool), and the pump.

2. INSTALLATION

HYPERTHERMIA

 

SPA  water  temperature  excess  38°C  (104°F)  may  be  injurious  to  health. 

 

Measure water temperature before entering SPA.were to strike a person.

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal 
body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase 
in the internal temperature of the body.

1.1 PRODUCT INFORMATION

Model

EFFECTIVE FITRATION

AREA

ICF 100

ICF 150

ICF 200

CODE

DESIGN FLOW RATE

Residential        Commercial

100

 150

200

FT²

9.29

13.94

18.58

100

 120

120

GPM

379

455

455

LPM

1.2 DIMENSIONS

ICF 100

Outer dimension diagram

ICF 150

ICF 200

CM

53.05

23.00

46.40

8.20

IN

20.9

9.05

18.30

3.20

CM

53.05

31.50

46.40

8.20

IN

20.90

12.40

18.30

3.20

CM

53.05

43.80

46.40

8.20

IN

20.90

17.24

18.30

3.20

A

B

C

D

9140401

9140402

9140403

A

B

D

C

[ Filter rate for residential use based on 1GPM/ft². Recommend Flow Rate for 2” piping is 90

x  150 GPM ]

 

≤  ≤

Summary of Contents for ICF 100

Page 1: ...USER MANUAL STRIVE FOR CLEAR WATER www emauxgroup com SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Manual EMAUX WATER TECHNOLOGY CO LTD Models ICF 100 ICF 150 ICF 200 EMFI22021501 ...

Page 2: ...repositioning valve s and before beginning the assembly disassembly or any other service of the circulating system 1 Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing open the manual air release valve Wait until all pressure is relieved 3 Whenever installing the filter closure follow the filter closure warnings exactly 4 On...

Page 3: ...exceed the maximum operating pressure of the system components Exceeding these limits could result in a component failing under pressure This instantaneous release of energy can cause the closure to separate and could cause severe personal injury or death if they were to strike a person This product should be installed and serviced only by a qualified pool professional 1 The filter system should b...

Page 4: ...re reading turn the outer dial START arrow marker to the pressure gauge pointer position When the pressure rises to or above the CLEAN FILTER marker it is time to clean or replace your filter cartridge elements By recording the initial starting pressure with clean filter elements a determination can be made when the filter cartridge elements should be replaced rather than cleaned After the filter ...

Page 5: ...en hose After hosing the cartridge for best results carefully brush the pleated surface to remove fine particles Do not pressure wash as it can damage the filter element You may find some debris on the cartridge pleats which may not have been removed with hosing 4 4 FILTER REASSEMBLY INSTRUCTIONS 4 4 1 RE INSTALLING CARTRIDGES 1 Remove filter tank sealing O Ring 2 With a clean cloth wipe the lower...

Page 6: ...0 to 400 ppm 0 2 ppm Maximum 1 0 to 3 0 ppm 60 to 80 ppm 4 5 REMOVING THE MANUAL AIR RELEASES VALVE The filter comes with a preinstalled manual air relief valve Servicing the Manual Air Release Valve MAR should be carried out by pool professionals only by carefully following the instructions 1 Turn off all system circulation pumps and all electric power on the equipment pad 2 Set all system valves...

Page 7: ...tack or g as a result of service by anyone other than Emaux authorized reseller or authorized agent EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY EMAUX MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMAUX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE...