6. TERMS OF THE WARRANTY

The pump does not 

come on 

Insufficient  power supply 

Check whether the pump plate data 
corresponds to that of the electricity network.

As original purchaser of this equipment have purchased from Emaux Water Technology Co Ltd, 
through Authorized International Distributor or Dealer, warrants its products free from defects in 
materials and workmanship under normal use during warranty period. The warranty period begins on 
the day of purchase and extends only to the original purchaser. It is not transferable to anyone who 
subsequently purchases the product from you. It excludes all expendable parts.
During the warranty period, Emaux authorized reseller will repair or replace defective parts with new 
parts or, at the option of Emaux, ser viceable used parts that are equivalent or superior to new parts in 
performance.

This Limited Warranty extends only to products purchased from Emaux authorized reseller. This 
Limited Warranty does not extend to any product that has been damaged or rendered defective
(a) as a result of accident, misuse or abuse;
(b) as a result of an act of God;
(c) by operation outside the usage parameters stated herein;
(d) by the use of parts not manufactured or sold by Emaux;
(e) by modification of the product;
(f) as a result of war or terrorist attack ; or
(g) as a result of ser vice by anyone other than Emaux authorized reseller or authorized agent.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, EMAUX MAKES NO OTHER WARRANTIES 
EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE. EMAUX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED 
IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE 
LIMITED TO THE TERMS OF THIS EXPRESS LIMITED WARRANTY.

Broken diaphragm

Excessive backpressure

Operation without liquid

Membrane not secured

correctly 

Check the system pressure. Check whether 
the injection valve is blocked. Check whether 
there are any blockages between the deliver y 
valves and the injection point.

Check the presence of the foot filter (valve). Use a 
level probe that stops the pump when the chemical 
product in the tank has run out. 

If the membrane has been replaced, make 
sure that the same is correctly tightened.

Summary of Contents for CTRL Series

Page 1: ...USER MANUAL Model Ctrl Series EMAUX CTRL SERIES EMPU22071140...

Page 2: ...OR USER Automatic Dosing pump 4 1 Control panel 4 2 Programming menu 4 2 1 Setting the Language 4 2 2 Functional setting 4 2 3 pH calibration Menu 4 2 4 Potential Redox Calibration Menu O R P 4 2 5 Al...

Page 3: ...0 mA otherwise could result in electrical shock causing serious bodily injuries including death 1 INTRODUCTION INSTALLATION and Start Up MANUAL FOR CTRL SERIES DOSING PUMP Manual dosing pump CTRL4 CTR...

Page 4: ...4 pH CTRL 7 pH CTRL 20 pH CTRL4 ORP CTRL 7 ORP CTRL 20 ORP 1 Regulation area 2 Dosing head 3 Delivery connector 4 Priming valve 5 Base support Optional MATERIALS USED IN THE PUMP HEAD STANDARD BODY PV...

Page 5: ...rk is compatible with that indicated on the pump label If you are injecting in pressurized pipes always make sure that the system pressure does not exceed the maximum working pressure indicated on the...

Page 6: ...plumbing characteristics of the pump If you need to use longer pipes it is important that you use pipes of the same dimensions as those supplied with the pump For external applications in which the D...

Page 7: ...tion level Avoid installing the pump directly exposed to sunlight Install the pump so that any inspection and maintenance operations are easy to carry out then secure the pump firmly in order to preve...

Page 8: ...amage the pump If possible install a safety valve at the outlet to avoid damage to the pump when the pump is blocked Suction tube and priming valve Tube connection make sure the tube is well connected...

Page 9: ...ed at the same time as the keys it increases or lowers a value dependent on the selected operating mode During programming it carries out an enter function meaning that it confirms entry to the variou...

Page 10: ...ion No Save Exit Save Exit PROG Prog Configuration Setpoint 7 00 pH Setpoint Type Acid Prop Bland 0 50 pH Alarm Band 2 00 pH O F Alarm 0m Resolution 0 01m Probe Calib On Temperature Man 25 Pump Calibr...

Page 11: ...ing Operation Display during Setting MODE key PROG enter PROG Configuration Configuration Pump Functions P100 Alarm Relay N Open Language English enter enter PROG enter PROG Configuration Configuratio...

Page 12: ...ay during Setting MODE key Setpoint Type Acid Setpoint 7 00 pH Pump Funtions Pump Functions pH Measure PROG Prop Band 0 50 pH Alarm Band 2 00 pH O F Alarm 0m Resolution 0 01 Probe Calib On Temperature...

Page 13: ...p Functions Redox Measure enter Setpoint 650 mV Setpoint Type Low Prop Band 50 mV Alarm Band 200 mV O F Alarm 0 m O F Alarm On max Set point type minimum max Setpoint type High Low Flow sensor status...

Page 14: ...then on again by disconnecting its electrical power supply The setting can be disabled Off factory default or else can be set to a delay time ranging from 1 to 60 minutes The alarm and pulse LED indi...

Page 15: ...ill be flashing While the time delay is in progress the function can be disabled by accessing the menu and setting the time to Off Press to access the modification option and use the and buttons to se...

Page 16: ...graph 10 Password Operation By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line ind...

Page 17: ...mming This makes it possible to set the pump when the level sensor alarm is activated In other words you can decide whether to stop dosage Stop or simply activate the alarm signal without stopping dos...

Page 18: ...peration The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key thenusing the keys to set the new value N OPEN or N CLOSED Press to confirm...

Page 19: ...nd you should press to exit calibration the pump exits automatically after 4 seconds If the quality is above 50 the value is shown on the display and after pressing the key the value of pH 7 00 flashe...

Page 20: ...f 465 mV should now flash on the display Insert the probe in your solution and use the keys to display the value of the solution in your possession then confirm by pressing the key and begin the calib...

Page 21: ...oblem Possible Cause Solution The pump is working properly but the dosage is interrupted Valve blockage Excessive suction height Excessively viscous liquid Insufficient flow capacity Valve leakage Exc...

Page 22: ...d defective a as a result of accident misuse or abuse b as a result of an act of God c by operation outside the usage parameters stated herein d by the use of parts not manufactured or sold by Emaux e...

Page 23: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...

Reviews: