PROG
PROG
Configuration
Pump Calibration
enter
enter
0.23 cc/stroke
enter
Pump Calibration
Manual
Pump Calibration
Automatic
enter
Pump Calibration
cc/stroke 0.23
Automatic Cal.
Start 100 stroke.
enter
Automatic Cal.
Strokes 100
Automatic Cal.
ml 20
enter
4.2.2
.
7
Paragraph 7 – Delay calibration Setting
Programming
Operation
Used to set a pump operation delay after calibration of the
probe (Redox or pH).
The setting can be disabled (Off - factor y default) or else can
be set to a delay time ranging from 1 to 60 minutes.
The alarm and pulse LED indicators will flash while the delay
time is in progress (1 sec ON - 1 sec Off) and the countdown
will be shown on the display in seconds. If the pump is in
Stop mode, the LEDs alone will be flashing. While the time
delay is in progress, the function can be disabled by
accessing the menu and setting the time to Off.
Press to access the modification option and use the
a
n d buttons to set the desired value. Press
to confirm and return to the main menu.
4.2.2
.
8
Paragraph 8 – Flow Calibration
Programming
Operation
The memorised cc value per strike appears in
the main menu. It can be calibrated in two
different ways:
MANUAL – manually enter the cc value per
strike using the keys and confirm by
pressing the key.
AUTOMATIC – the pump makes 100 strikes,
which are started by pressing the key. At
the end of this process, enter the quantity
sucked up by the pump using the
keys and confirm by pressing the key.
The entered figure will be used in flow
calculations.
PROG
enter
PROG
Configuration
Configuration
Pump Functions
P100%
Alarm Relay
N.Open
Language
English
enter
enter
D e l a y P o w e r O N
o f f
D e l a y C a l i b .
o f f
P14