4.2.2
.
9
Paragraph 9 - Statistics
Operation
The main menu displays the pump operation times. By
pressing the key you can access other statistics:
Strokes = number of strokes made by the pump
Q.ty (L) = quantity dosed by the pump in litres; this figure
is calculated on the basis of the memorised cc/stroke value
Power = number of pump starts
Reset = use the to reset the counters
(YES) or other wise (NO), then confirm by pressing the
key.
Pressing the key will take you back to the main menu.
4.2.2
.
10
Paragraph 10 – Password
Operation
By entering the password, you can enter the programming
menu and see all the set values. The password will be
requested whenever you seek to modify them.
The flashing line indicates the number than can be modified.
Use the key to select the number (from 1 to 9), and the
key to select the number to be modified. Confirm by
pressing the key. By setting “0000” (default), the
password is eliminated.
P15
Programming
Programming
PROG
PROG
Configuration
Statistic
enter
enter
Hours 10
enter
Statistic
strokes 1000
Statistic
Q.ty(L) 100
Statistic Reset
NO
Statistic
Power 10
Statistic
Reset 10
ESC
Statistic
Hours 10
PROG
PROG
Configuration
Password
enter
****
enter
Password
0000