EP-360 Micro panel printer
34/68
character (CODE A, CODE B, or CODE C), which selects the first
code set.
②
Special characters are defined by combining two characters "{" and
one character. The ASCII character "{" is defined by transmitting "{"
twice consecutively.
Specific character
Transmit data
ASCII
Hex
Decimal
SHIFT
{S
7B, 53
123,83
CODE A
{A
7B, 41
123,65
CODE B
{B
7B,42
123,66
CODE C
{C
7B,43
123,67
FNC1
{1
7B,31
123,49
FNC2
{2
7B,32
123,50
FNC3
{3
7B,33
123,51
FNC4
{4
7B,34
123,52
"{"
{{
7B,7B
123,123
[Example] Example data for printing "No. 123456"
In this example, the printer first prints "No." using CODE B, then prints
the following numbers using CODE C.
GS k
73 10 123 66 78 111 46 123 67 12 34 56
·
If the top of the bar code data is not the code set selection character,
the printer stops command processing and processes the following
data as normal data.
·
If the combination of "{" and the following character does not apply
any special character, the printer stops command processing and
processes the following data as normal data.
·
If the printer receives characters that cannot be used in the special
code set, the printer stops command processing and processes the
following data as normal data.
·
The printer does not print HRI characters that correspond to the shift
characters or code set selection characters.
·
HRI character for the function character is space.
·
HRI characters for the control character (<00>H to <1F>H and
<7F>H) are space.
<Others> Be sure to keep spaces on both right and left sides of a bar code.
(Spaces are different depending on the types of the bar code.)
[Reference]
GS H
,
GS h
,
GS w
UnRegister
ed