The  following  residual  risks  do 
principally  exist  when  operating 
submersible  pumps  and  can  not 
be  fully  eliminated  –even  by 
employing safety devices. 

A

 

Hazard by ambient 

conditions!

Do  not  use  the  pump  in  hazardous 
loca-tions  or  near  inflammable 
liquids  and  gases!

B

 

Danger! Risk of electric 

shock!

Do  not  touch  the  plug  with  wet 
hands! To unplug  always  pull  at  the 
plug,  not  the  power cable. 

Connect only to an earthed outlet 
that is properly  installed,  earthed 
and  tested.  Mains voltage and fuse 
protection must correspond to those 
stated in the "Technical 
Specications".

Do  not  buckle,  squeeze, 
drag  or  drive  over power 
cable and extension cables; 
protect from sharp edges. 
Place extension cable so 
that it can not get into the 
fluid to be pumped. 
Always  unplug  before 
servicing  the  pump. 

A

 

Danger by pump failings!

Before each use check the 
pump, espe-cially the power 
cable and plug for possi-ble 
damage. Risk of fatal electric 
shock! 
A damaged pump must be 
workmanlike repaired before 
it can be used again. 

Do not attempt to repair the 
pump your-self! When 
repaired inexpertly there is a 
hazard  of  fluid  entering  the 
electrical  parts of the pump.
-The water may be 
contaminated by escaping 
lubricating oil/lubricant. 

5.1Discharge hose connec

tion

x

 

Attach discharge hose to the 

discharge port (3).

5. Prior to Operation

3

EN

5.2

 

Installation 

x

 

Space required approx. 

30 cm  x  30  cm. 

x

 

The pump must not be 

submerged deeper  into  water 
then  stated in  the "Technical 
Specifications". 

x

 

Place pump so that the suction 

inlet can not be blocked by foreign 
objects (stand on a base, if 
necessary).

x

 

Ensure sufficient upright stability. 

A

 

Caution!

Do not lift pump at the cable or

 

discharge hose; both are not

 

designed for the tensile load by 
the

 weight of the pump. 

1. Submerge 

pump 

at 

an

angle  to avoid  an  air  cushion
at  the  under-side,  which
would  prevent  priming.  Once
the pump is submerged, it can
be set into an upright position.

2. Lower  pump  to  the  bottom  of

the  fluid  container.

A

 

Caution!

When pumping contaminated

 

fluids install a suction strainer 
to pro-tect pump from sand and 
dirt. 

- Only connect the pump to a 
power outlet with protective 
contact.
- Before connecting the pump to 
the mains 
- The pump must be supplied 
through a residual current device 
(RCD) having a rated residual 
operating current not exceeding 30 
mA.

- If the device is not being  used, 
when being transported  and before 
maintenance,  remove the power 
cord from  the socket to avoid  
uncontrolled start of the device

 

When connecting the pump,  make 
sure that the mains  voltage 
complies with the  voltage stated on 
the pump  nameplate.

- Before each use, check if the 
supply cord or plug is damaged. If 
the supply cord or plug is damaged, 
it must be replaced by the 
manufacturer, its service agent or 
similarly qualified persons in order 
to avoid a hazard.

x

 

To start the submersible pump 

plug power cable in. 

x

 

Unplug to stop the pump.

Use a strong rope,  fastened to the 
cable eye, to lower the pump.
The pump can also be operated  
when suspended by a rope.

6.1

 

Switching ON and OFF 

x

 

The submersible pump will start 

pumping as soon as it is being 
con-nected to the mains. 

x

 

The submersible pump is 

switched  OFF  by  unplugging. 

A

 

Caution!

To avoid the pump running

 

dry, 

unplug before air is being

 

primed. 
6.2

 

Pump characteristic

 curve

 

The  pump  characteristic  curve 
shows  which  pump  capacity  is 
possible  in  dependance on the 
delivery head. 

6. Operation

4

Та

ше

в

-

Га

лв

ин

г

 

ОО

Д

 

www.tashev-galving.com

Summary of Contents for SRP 15502 DR Basic line

Page 1: ...e ovih uputa za uporabu i sigurnosnih napomena Prije pu tanja u pogon pro itajte i uva ite uputstva za upotrebu i napomene bezbednosti Pred pou it m si pre tajte n vod na obsluhu a uistite sa e ste mu...

Page 2: ...e tamparske gre ke i odstupanja u boji Technick zmeny chyby tla ov chyby a farebn odch lky s vyhraden Los cambios t cnicos errores errata y el color desviaciones son reservados TR ES DK Tekniske ndrin...

Page 3: ...English Originaltext Original Texte d origine 1 Deutsch 7 Sloven ina 13 Hrvatski 19 C 25 M 31 37 Slovensky 43 w w w t a s h e v g a l v i n g c o m...

Page 4: ...w w w t a s h e v g a l v i n g c o m...

Page 5: ...OPERATING INSTRUCTION SUBMERSIBLE PUMP 3 1 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 6: ...iew 1 Carrying handle 2 Float switch height adjustment 3 Hose adapter for pressure connection 4 Float switch 5 Pump casing 6 Power cable with plug SPE 15502 DR EN 2 4 1 2 3 5 6 w w w t a s h e v g a l...

Page 7: ...the one described here If you have no expe rience with this type of pump you are strongly advised to seek compe tent advise and guidance from an experienced person before operat ing this pump Keep al...

Page 8: ...ity A Caution Do not lift pump at the cable or discharge hose both are not designed for the tensile load by the weight of the pump 1 Submerge pump at an angle to avoid an air cushion at the under side...

Page 9: ...delivery head see Technical Specifications x Discharge hose kinked Straighten discharge hose x Discharge hose leaky Seal discharge hose tighten screw fittings Pump runs very noisily x Pump primes air...

Page 10: ...Notes 6 w w w t a s h e v g a l v i n g c o m...

Page 11: ...BEDIENUNGSANLEITUNG TAUCHPUMPE D 7 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 12: ...ick D 1 Trage handle 2 Schwimmerschalter H he adjustment 3 Schlauchadapter f r Druck Verbindung 4 Schwimmerschalter 5 Pumpen casing 6 Netzkabel mit Stecker SPE 15502 DR 8 4 1 2 3 5 6 w w w t a s h e v...

Page 13: ...gefahren bestehen grunds tzlich beim Betrieb von Tauch pumpen sie lassen sich auch durch Sicherheitsvorkehrungen nicht v llig beseitigen A Gefahr durch Umgebungseinfl sse Inhaltsverzeichnis 3 Einsatzg...

Page 14: ...ziehen Sie immer den Netzstecker um ein unkontrolliertes Einschalten zu vermeiden Bevor Sie die Pumpe ans Stromnetz anschlie en vergewissern Sie sich dass die Spannung den Angaben auf dem Typenschild...

Page 15: ...e und Sicherung pr fen x Zu geringe Netzspannung Verl ngerungskabel mit ausrei chendem Aderquerschnitt verwenden siehe Technische Daten xMotor berhitzt Motorschutz ausge l st S Ursache der berhitzung...

Page 16: ...Anleitung A Multiadapter Anschluss Einlaufseite 1 AG Anschluss Auslaufseite 1 AG 3 4 AG T lle 1 3 4 11 Lieferbares Zubeh r B Winkelschlaucht lle Anschluss Einlaufseite 1 IG Anschluss Auslaufseite 1 I...

Page 17: ...NAVODILA ZA UPORABO POTOPNA RPALKA SLO 13 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 18: ...aj 2 Plovno stikalo za nastavitev vi ine 3 Tla ni priklop 4 Plovno stikalo 5 Ohi je rpalke 6 Napajalni kabel z vti em 1 Potopna rpalka pogled SPE 15502 DR 14 4 1 2 3 5 6 w w w t a s h e v g a l v i n...

Page 19: ...i ali podaritvi stroja novemu lastniku dajte tudi vsa navodila in dokumentacijo Proizvajalec ne odgovarja za Posebno pozornost nameniti izjavam ozna enim z naslednjimi besedami Pozor Ka e na mo nost t...

Page 20: ...rokovnjaki Periodi no vzdr evanje Da bo rpalka delovala im bolj optimalno jo je potrebno periodi no pregledati in negovati To predvsem velja e rpalka deluje slabih pogojih in dolgo asa Letni pregled 1...

Page 21: ...zavrti Takoj izvlecite vti z izvija em o istite tujek izvlecite izvija in ponovno vklopite rpalko Sesalna vi ina je prevelika preverite sesalno vi ino po teh podatkih vgradite protipovratni ventil in...

Page 22: ...Notes 18 w w w t a s h e v g a l v i n g c o m...

Page 23: ...UPUTE ZA UPOTREBU POTOPNA PUMPA CRO 19 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 24: ...a 1 Ru ka 2 Prekida za pode avanje visine 3 Adapter za priklju ak tla nog crijeva 4 Plutaju i prekida 5 Ku i te pumpe 6 Energetski kabel s utika em SPE 15502 DR 20 4 1 2 3 5 6 w w w t a s h e v g a l...

Page 25: ...upotrebe 3RWRSQD pumpa je namenjena za crpanje iste vode u ku i i pored nje kao to je Ove upute su napisane kako bismo Vas vode u radu i kori tenju na najsigurniji na i da osiguraju to radni vijek Ev...

Page 26: ...amo kolovani serviseri mogu obavljati popravke pumpe Zbog curenja ulja sredstva za podmazivanje mo e se zaprljati voda Instalacija Pumpa mora biti postavljena u prostor dimenzije min 30x30cm Pumpa ne...

Page 27: ...ku ine koju pumpate Motor bruji ali se ne vrti Odmah izvucite utika o istite usisni dio i ponovno uklju ite pumpu Pumpa ne radi pravilno Usisna visina je prevelika provjerite usisnu visinu u teh podac...

Page 28: ...Notes 24 w w w t a s h e v g a l v i n g c o m...

Page 29: ...UPUTSTVA ZA UPOTREBU SRB POTOPNA PUMPA 25 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 30: ...ed SRB 1 Ru ka 2 Prekida za pode avanje visine 3 Adapter za priklju ak tla nog crijeva 4 Plutaju i prekida 5 Ku i te pumpe 6 Energetski kabal sa utika em SPE 15502 DR 26 4 1 2 3 5 6 w w w t a s h e v...

Page 31: ...red nje kao to je SRB 2 Pa ljivo pro itati pre upotrebe Ova uputstva su pisana na na in koji e vam omogu iti sigurnu upotrebu ure aja Ova uputstva bi trebala biti kori ena na slede i na in Pro itajte...

Page 32: ...ju ujete povucite za utika nikada za kabal Uzemljena uti nica produ nog kabla mora biti za ti ena od preplavljivanja Nemojte savijati gnje iti vu i ili voziti preko napojnog i produ nog kabla a tititi...

Page 33: ...ohladi i ponovo upalite pumpu Proverit uzrok pregrevanja Proverite temperaturu te nosti koju crpate Motor bruji ali se ne okre e Odmah isklju ite pumpu izvadite elemen koji je zako io pumpu i ponovo...

Page 34: ...Notes 30 w w w t a s h e v g a l v i n g c o m...

Page 35: ...MK 31 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 36: ...1 SPE 15502 DR 1 2 3 4 5 6 32 4 1 2 3 5 6 w w w t a s h e v g a l v i n g c o m...

Page 37: ...3 3 35 4 4 1 2 J Y XJ J Y x x x 1 2 3 x x x 1 x 33 4 2 89 A B C D D B FGH ICFGJGI KCD D B L A F NDODJCD DF DFD A F C 9 LD D FD P O D CG I D O Q I C D B PDF D GCLDD I B G9 P 9 D C FD D B BS I FDL O DI...

Page 38: ...x 3 3 x x x FI RCD residual current device x x x x 30mA 6 x x Q 6 2 5 2 x 30 30 x x x i eF 1 2 x x 5 5 1 6 1 34 w w w t a s h e v g a l v i n g c o m...

Page 39: ...7 F c W 7 1 F X 1 2 3 7 2 Y F x x x x i x x x x i x 9 100 11 8 1 8 10 SPR 15502 DR 35 w w w t a s h e v g a l v i n g c o m...

Page 40: ...36 w w w t a s h e v g a l v i n g c o m...

Page 41: ...BG 37 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 42: ...1 SPE 15502 DR 1 2 3 4 6 5 BG 38 4 1 2 3 5 6 w w w t a s h e v g a l v i n g c o m...

Page 43: ...11 12 HE 3 BG A 4 C T OD 9 G UPI B DO9 FOI V D B L A F NDODJ CD DI DFD GA I C 9 LD DFD P O O D D 9D C D GC D D O P D C C FD J I C S I UW O UV P O 9 DIN VDE 0100 702 738 A P 39 2 35 C w w w t a s h e...

Page 44: ...3 BG 30 mA 12 5 P A A 3 30 x30 1 2 6 A A 40 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 45: ...BG 7 1 2 3 1 2 3 8 J 12 A A 12 9 A 10 100 41 w w w t a s h e v g a l v i n g c o m...

Page 46: ...42 w w w t a s h e v g a l v i n g c o m...

Page 47: ...SK N VOD NA OBSLUHU Ponorn erpadlo 43 SPR 15502 DR w w w t a s h e v g a l v i n g c o m...

Page 48: ...ad pr stroja SPE 15502 DR 1 Rukov na uchopenie 2 prava v ky plav ka 3 Hadicov adapt r na tlakov pr poj 4 Plav k 5 Obal erpadla 6 Nap jac k bel so z str kou 44 4 1 2 3 5 6 w w w t a s h e v g a l v i...

Page 49: ...cirkul ciu zabr neniu tvorby hniloby na prev dzku jazierok a tokov Pozor Maxim lna teplota erpanej tekutiny 35 C erpan tekutiny obsahuj ce br sne mirg uj ce l tky napr piesok zni uj ivotnos pumpy 4 Be...

Page 50: ...plne odvinut Sie ov a predl ovac k bel nel ma nemlia di netrha a neprech dza vozidlom chr ni pred ostr mi hranami olejom a hor avou Predl ovac k bel polo i tak aby sa nemohol dosta do dopravovanej tek...

Page 51: ...rpadlo nas va vzduch Uistite sa e je dostato n z soba vody erpadlo pri ponoren dr te ikmo Opravy A A A 47 1 Skontrolova obal erpadla a k bel i nie s po koden 2 erpadlo vypl chnu istou vodou Pevne dr i...

Page 52: ...max Temperatura dotoka vode max o C 35 Dimensions H W L Dimenzije H W L mm 166 185 335 Gewicht Weight Te a Te ina kg 6 8 35015501100 1 G1 11 4 G11 2 Nennaufnahmeleistung Power consumption 0 Anschluss...

Page 53: ...on in case of mechanical or natural faliures in case of unprofessional or negligent operating with the appliance in case there is no warranty certificate and original invoice for components subject of...

Page 54: ...H DUDQWQL URN SR LQMH GD WH H VD GDQRP SURGDMH WR GRND MHWH JDUDQWQLP OLVWRP L RUJLQDOQLP UD XQRP 1H RGJRYDUDPR D QLNDNYX WHWX JXELWDN R WH HQMH VWYDUL NRMD SUL OD L NRUL HQMHP LOL QHPRJX QR X XSRWUHE...

Page 55: ...nc ijo v sk ladu z ustrezno dr avno zakonodajo Izdelek ki ne bo popravljen v skladu z ustrezno dr avno zakonodajo bomo brezpla no zamenjali z novim ali pa vam povrnili stro ke nakupa V primeru da popr...

Page 56: ...REBIOP w w w t a s h e v g a l v i n g c o m...

Page 57: ...ipo SPR 15502 DR 2006 95 EC 2004 108 EC EN 55014 1 EN 55014 2 EN 60335 1 EN 60335 2 41 EN 50366 EN 61000 3 2 EN 61000 3 3 EN 62233 2008 CE Kennzeichnung wurde angebracht CE marking was affixed Le marq...

Page 58: ...Notes w w w t a s h e v g a l v i n g c o m...

Page 59: ...mana 10 Brezje 10431 Sveta Nedelja Tel 385 1 3325 515 e mail servishr rem maschinen com www rem maschinen com AT STERREICH MK Makweld d o o Londonska 9a 1000 Skopje Tel 389 2 3173 058 e mail service...

Page 60: ...Maschinen GmbH sterreich Tel 386 8 2000 958 Fax 386 8 2000 e mail office at rem maschinen com Rheinland Elektro Maschinen GROUP PC Komend 1 10 SI 1218 Komenda EU E Mail exp rem maschinen com www rem m...

Reviews: