18
User Manual CAT 27 scales series
ELZAB S.A.
09
– SENDING MINUS
Setting value
Meaning
01^ ONLY POSITIVE
The negative result is considered as unstable and is
not sent.
02 POSITIVE & NEGATIVE
The negative result can be sent if it is stable.
10
– SENDING FRAME RESULT
Setting value
Meaning
01^ ONLY STABLE
The result frame is sent only when the result is stable.
02
STABLE & UNSTABLE
The result frame is sent after stabilizing the result or after the
time which is set in “
STABILITY WAITING TIME.
” If the
result hasn’t stabilized during that time the frame that is sent
contains the signs 0x20 in place of the result digits.
11
– STABILITY WAITING TIME
It specifies the waiting time for stabilizing the result. Time runs from the moment of requesting the
result by key pressing or serial interface request. The range of possible value settings is from 0 to
12 seconds. If the time was set at 0 seconds the result must be stable at the moment of requesting
the result. The default value of this parameter is 4 seconds.
12
– RECEIVING DATA LOCK
Setting value
Meaning
01^ LOCK OFF
The scale receives the commands via the
PC
Connector.
02
LOCK ON
Receiving the data via the
PC
Connector is locked.
NOTE:
The automatic configuration with the ELZAB cash
registers is also inactive.
13
– TRANSMISSION KEY LOCK
Setting value
Meaning
01^ LOCK OFF
Data can be transmitted by using the
key.
02
LOCK ON
Transmission of the data by using the
key is locked.
14
– MESSAGE BEEP
Setting value
Meaning
01
BEEP OFF
The acoustic error signaling switched off.
02^ BEEP ON
The acoustic error signaling switched on.
15
– FIXED TARE
Setting value
Meaning
01^ AUTOMATIC TURN OFF
Single pressing of the
key switches on the tare but
doesn’t switch on the fixed tare. The fixed tare is switched on
only after pressing the key twice. If the “fixed tare” function is
switched off the tare will be automatically turned off after
weighing the articles and removing them from the platter.