ELZAB S.A.
User Manual CAT 27 scales series
19
Setting value
Meaning
02
ONLY FIXED TARE
Single pressing of the
key switches on the “fixed tare”.
After removing the loading the tare isn’t automatically
switched off.
16
– DISPLAY BACKLIGHT
Setting value
Meaning
01
NO TURNING OFF
The display backlight remains switched on.
02^ TURN OFF (15 SEC)
The display backlight is switched off after 15 or 30 sec.
of the scale inactivity.
03
TURN OFF (30 SEC)
17
– POWER SAVING MODE
Setting value
Meaning
01
SWITCHED OFF
Power saving mode is inactive.
02
TURN ON (10 MIN)
Power saving mode will be activated after 10, 30 or 60
minutes of the scale inactivity.
03^ TURN ON (30 MIN)
04
TURN ON (60 MIN)
18
– SCALES SYSTEM
This setting allows you to specify the number of the scale while it is working in the scale system.
The number can be entered by using the
key and confirmed by pressing the
key.
There is possible to enter the values in the range from 1 to 4. The default value is 1. Each of scales
working in the system should have different scale number entered.
19
– DISPLAY CONTRAST ADJUSTMENT
Setting value
Meaning
01
ADJ. MAIN DISPLAY
The function enables to adjust the contrast of the main display.
The function is inactive in the TFT colorful displays.
02
ADJ. ADDIT. DISPLAY
The function enables to adjust the contrast of the additional
display. The function is inactive in the TFT colorful displays.
20
– RESTORE FACTORY SETTINGS
This setting allows to restore factory settings marked with „
^
” sign. The selected settings should
be confirmed by pressing the
key.
21
– PROGRAM VERSION
The function enables to read the main program version of the scale and the display program version.
Main program version No.
Display program version No.
MEASURER: v.1.00
DISPLAY: v.2.22G
0.00
0.000
0.00
0.000
0.00
0.00