Control panel logic settings
L1
Automatic closing
Default
ON
OFF
Automatic closing off
ON
Automatic closing on
L2
Pause time
Default
30
1
1 s (minimum time)
180
180 s (maximum time)
L3
Pedestrian pause time
Default
20
1
1 s (minimum time)
180
180 s (maximum time)
L4
State on power up
Default
OP
CL
Gate in closed position:
The first step-step command opens the gate.
OP
Gate in open position:
The first step-step command closes the gate. If automatic closing is on, after the pause time
the gate closes
L5
Apartment block
Default
OFF
OFF
Apartment block function off
1
Ignores closing and stop commands in opening
2
Ignores closing and stop commands in opening and in pause
3
Ignores closing and stop commands in opening, in pause and in closing
L6
Rapid closing
Default
OFF
OFF
Rapid closing function off
1
Rapid closing in gate mode:
The control panel starts to count the clearance time (L7) from when the closing photocell is
released, when the clearance time expires it closes again.
2
Rapid closing in barrier mode:
The control panel starts to count the clearance time (L7) from when the closing photocell is
released, when the clearance time expires it closes again. If the closing photocell is occupied
again, it does not command it to reopen but to stop. When released again it continues with
closing. The closing photocell returns to normal operating after complete closure
L7
Clearance time (adjustable at intervals of 1 s)
Time after which the gate closes again if the rapid closing (L6) is on
Default
2
1
Minimum clearance time
10
Maximum clearance time