![Elvox SL24.W Installer Manual Download Page 16](http://html.mh-extra.com/html/elvox/sl24-w/sl24-w_installer-manual_2397992016.webp)
14
SL24.W
LGC
L8
Pre-flash
Flashing time of the flashing light before the gate starts to move
Default
OFF
OFF
Pre-flash disabled
3
3 s pre-flash
4
4 s pre-flash
5
5 s pre-flash
L9
Manned
Default
OFF
OFF
Manned function off
1
Step-step command disabled, remote controls not working. The control panel accepts only
open and close commands
2
Emergency manned. In normal standard operating conditions, with the safety devices occu
-
pied it works as manned.
L10
Step by step
Default
4
2
Step-step command operates in 2 steps: open, close, open...
3
Step-step command operates in 3 steps: open, stop, close, open...
4
Step-step command operates in 4 steps: open, stop, close, stop, open...
L11
Stop from step-step
Default
ON
OFF
Automatic closing disabled when a stop command from step-step is given
ON
Automatic closing not disabled when a stop command from step-step is given
L12
Stop from stop
Default
ON
OFF
Automatic closing disabled when a stop command from stop is given
ON
Automatic closing not disabled when a stop command from stop is given
L14
Operation in battery
Default
1
1
Standard operation
2
Normal operation with flashing light disabled
3
After a re-open command it stays open
4
When the main power supply is cut off it opens and remains open
L15
Economy
Default
OFF
OFF
Standard operation
1
Economy operation on. With the gate closed, it switches off the accessory power supply on
outputs 1 and 2. The outputs are powered again following a new command.
L16
Gate blocked open indicator
Number of minutes after which, with the gate partially or totally open, whatever the set
pause time, an alarm signal is sent (on the display and output configured as OAB)
Default
30
OFF
Indicator disabled
3
Minimum interval
60
Maximum interval
EN