PROGRAMMING
DIP SWITCH
Inputs
Description
N. 16 COM
Common for commands
N. 17 AP/CH
Makes the leaf open/close. See operating modes. NA contact.
N. 20 STOP
Stops all manoeuvres and until active it disables all manoeuvres. NC contact.
N. 18 APED
Pedestrian opening if the gate is closed. NA contact. Makes the gate close if the gate is open or stop-
ped.
N.19 COM
Common for safety devices
N. 21 FOTO
Photocell, NC contact, if the gate is closing it reverses the movement and until engaged it prevents the
gate from closing.
N. 22 STPA
Photocell on opening, stops all manoeuvres and until engaged it disables all manoeuvres. When relea-
sed: gate opens. NC contact.
N. 13 FCAP
Gate opening limit
N. 14 COM
Common limit
N. 15 FCCH
Gate closing limit
Outputs
Description
N. 9 (-) 2CAN
N. 11 (+)
Second channel output
if dip 3 = OFF it activates on receipt of the radio control.
If dip 3 = ON connect the TX photocells for test .
N. 10 (-) AUX
N. 11 (+)
(Pilot lamp)
24Vdc output for remote signalling of gate status:
If Dip 22 = OFF: off when the gate is closed, otherwise on.
If Dip 22 = ON: flashing during movement
N. 11 (+) 24V
N. 12 (-)
24Vdc output. Photocells power supply.
N. 4 LAMP
N. 5
Non-intermittent output for flashing light with card
Operating
Description
OBSTACLE WHEN CLOSING
The gate immediately reverses its movement.
OBSTACLE WHEN OPENING
The gate immediately reverses its movement for 1.5 sec and comes to a stop.
INPUTS, OUTPUTS AND OPERATIONS
DSW1
Function
ON
OFF
dip 1
Release / engagement stroke
Enabled
Disabled
dip 2
Pre-flashing
Enabled
Disabled
dip 3
2CAN Out
Power sup. TX Photocells (test)
Second radio control channel
dip 4
STPA In (partial stop on opening)
Resistive Edge
Photocell 2
dip 8
Photocell test
Enabled
Disabled
If DIP21 = ON the device functions in Open-Close mode. In this case:
APARTMENT BLOCK AUTOMATIC, SUPER AUTOMATIC, AUTOMATIC:
an OPEN pulse always results in opening and a CLOSE pulse in closing; once open, the gate remains paused for the specified pause
time. A CLOSE pulse during the pause sends a closing command. The courtesy function, if provided, remains active.
SEMI-AUTOMATIC, STEP OPERATION:
an OPEN pulse always results in opening and a CLOSE pulse in closing.
DSW2
Function
ON
OFF
dip 21
Open-Close mode
Enabled
Disabled
dip 22
AUX out
Flashing beacon
Warning light
GB