The table of parameters currently available is as follows:
Parameter
Minimum value
Maximum value
Default setting
Notes
Messag. language
0 = Local language
1 = English
Local language
Language of the messages shown on the
switchboard display.
Switchboard ID
1
4
1
In Elvox 2-wire systems, up to a maxi-
mum of four switchboards can be used
with ID from 1 to 4.
Code digits #
Natural
8
Natural
The numbering schedule can follow the
natural order 1..200, or have 4 digits from
0000 to 9999, or 8 digits from 00000000
to 99999999.
Devices numbr
0000(0000)
9999(9999)
Blank
Assignment of correspondence between
4 / 8 digit and natural numbering if the
no. code numbers is not set as natural.
Search all pbk.
No
Yes
No
When the value is set to Yes, with a
name length of 0, the entire agenda can
be viewed.
Device names
2 x 200 names, each of 16 characters.
Program Password
000000
999999
654321
Code for entry to parameters menu: to
modify or read parameters in this table.
Keyboard Password
000000
999999
654321
Keyboard lock: a padlock icon is
displayed.
Lock time
0 [sec]
255 [sec]
1
Lock timing:
0= lock disabled
Function 1 time
0 [sec]
255 [sec]
1
F1 criteria timing:
0= 0.5 sec.
Function 2 time
0 [sec]
255 [sec]
1
F2 criteria timing:
0= 0.5 sec.
Common Lock
0
15
0, 0, 0, 0
Blank
Common F1
0
15
0, 0, 0, 0
Blank
Common F2
0
15
0, 0, 0, 0
Blank
Keyboard beep
No
YES
YES
If this parameter is set to Yes, a beep is
emitted each time a key is pressed.
Ton repetition
Not assigned
Function F2
Not assigned
Choose what output you want to operate
as call repeater: door lock or F1 or F2
(from version 4).
Int. call filter
0= filter disabled
1= filter enabled
0
When enabled, this filters calls from all
system devices (interphone/ monitor)
Warn. swcb. time
0 o 2 [min]
50 [min]
one time! = 0
One time! = message indicating swit-
chboard presence sent to the master
panel after a reset once only;
When Swb warning Time is set between
2 and 50 min. the switchboard presence
message is set periodically at the interval
set in Swb. warning time minutes.
Clock
01/01/05
00:00
Interphone/monitor
configuration
Enables configuration of individual
monitors/interphones