Table for entrance panels and electronic units for DUE FILI ELVOX (Two Wire Elvox) system
Type of panel
Electronic unit for
1200, 1300 Series
entrance panel
Electronic entrance
panel series 8000
Electronic entrance
panel series PATAVIUM
Electronic entrance
panel series 3300
Electronic entrance
panel series letter box
Alphanumeric audio en-
trance panel
12F4
89F4
89F4/T
39F4
25F3/8 - 2930
Push-button audio en-
trance panel
12F3 - 12F3/3
89F3, 89F3/2,
89F3/1, 89F3/0
89F3/T, 89F3/2T,
89F3/1T, 89F3/0T
39F3
25F3/8 - 2930
Alphanumeric video en-
trance panel
12F7
89F7/C
89F7/CT
39F7
25F3/8 - 2559
Push-button video en-
trance panel
12F5 -12F5/3
89F5/C, 89F5/C2,
89F5/C1, 89F5/C0
89F5/CT, 89F5/CT2,
89F5/CT1, 89F5/CT0
39F5
25F3/8 - 2559
Conductor section
Terminals
Ø up to 10 m
Ø up to 50 m
Ø up to 100 m
Ø up to 300 m
Bus: 1, 2, B1, B2 ( )
0,5 mm
2
0,5 mm
2
0,75 mm
2
1 mm
2
Cable Elvox
Type 732H, Type 732I
Type 732H, Type 732I
Type 732H, Type 732I
Type 732H, Type 732I
Electric lock
1,5 mm
2
-
-
-
Other: -, +U, +I, -L (
#
)
1 mm
2
1 mm
2
1,5 mm
2
2,5 mm
2
Video
Coaxial cable 75 Ohm type RG59 o RG11 (only for the connection of any external cameras type CCTV)
On Two-Wire installations use cable type 732H or 732I for a maximum distance of 300 metres.
# Additional power supplies (type 6923, 6582, 6982) must be installed as close as possible to the device to which they are to be connected.
BUS TERMINATION FOR ELVOX TWO-WIRE INSTALLATIONS
This note applies to all devices with ELVOX TWO-WIRE technology equipped with “BUS termination connector or dip-switch”, which is identified by the
screen-printed letters “ABC” and marked on the wiring diagrams with
*
.
For correct adaptation of the line, make the setting according to the following rule:
Maintain position “A” if the BUS enters and exits from the device;
Move to position “B” (if Elvox cable) or to position “C” (if CAT5 twisted pair cable) if the BUS line terminates in the device itself.
“A” = NO TERMINATION
“B” = TERMINATION 100 ohm
“C” = TERMINATION 50 ohm
INSTALLATIONS WITH PASSIVE DISTRIBUTOR 692D
(DIN rail version)
ALWAYS use output 1 on distributor type 692D (the only one that has no termination jumper).
For termination of type 692D: If outputs “OUT”, “2”, “3” or “4” are not used, KEEP the jumper on the “TOUT”, “T2”, “T3” or “T4” connector. The default
“TOUT” connector is in the “100” position (Elvox cable), position it to “50” only if using a CAT5 twisted pair cable.
INSTALLATIONS WITH PASSIVE DISTRIBUTOR 692D
(non-DIN rail version)
For termination of type 692D (non-DIN rail version): If the “OUT” output is not used, KEEP the jumper on connector “A”. If the “OUT” output is used, RE-
MOVE the jumper from connector “A”.
INSTALLATIONS WITH ACTIVE DISTRIBUTOR 692D/2.
The termination jumper must be positioned on “B” (for Elvox cable) or on “C” (for CAT5 twisted pair cable) IF AND ONLY IF the BUS terminates at the de-
vice itself. It must be left on “A” if effecting entry-exit using terminals 1-2 on 692D/2.
*
GB