PUSHBUTTON REMAPPING
Enables modification to the code sent by a pushbutton, regardless of
its physical position assigned with the hardware programming. This
enables use of a pushbutton to call an interphone /monitor that has al-
ready been assigned a different code.
Default value = all push-buttons associated with a specific physical
code
On entry to parameter editing mode, the LEDs start flashing; to start
remapping, press the pushbutton START/YES (top left).
After pressing the pushbutton START/YES, press the call pushbutton of
the panel to be remapped. A general call is made from the panel to all
interphones/monitors in the rest condition (not in conversation); the in-
terphones/monitors with handset raised will emit a 3-tone ascending
scale from the loudspeaker.
From this moment the user has a 30-second interval to press, on the in-
terphone/monitor to be associated, the lock push-button.
The panel loudspeaker emits a low tone; this also occurs when the 30-
second time interval elapses.ù
Press the pushbutton START/YES (top left) to remap other push-but-
tons or END (bottom left) to proceed with the other parameters.
To restore the default value (Hardware value) of a pushbutton, instead
of pressing START/YES, press STOP/NO and then the pushbutton to
restore the default value and end the procedure.
During this procedure, if the lock pushbutton on the interphone/monitor
concerned is pressed, the panel lock is activated. To eliminate this
event, enable the parameter PANEL BLOCK.
ADVANCED PARAMETER PROGRAMMING
Refer to the instructions for programmer type 950C.
-
F1 TIME
To be programmed at user's discretion. This is the activation time of
the device connected between ter12V / F1. Default value = 1
second, minimum value 0,5 s., maximum value 255 s.
On entry to parameter editing mode, start the count of the time to be
memorise by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at
intervals of 500ms ON/500ms OFF to enable calculation of the time
elapsed, 1 flash = 1 s. (e.g. 10 flashes = 10 s.).
Press the pushbutton END to proceed with the other parameters.
To reset the time to 0 (0.5 s.) press the pushbutton STOP/NO in place
of the pushbutton START/YES.
-
F2 TIME
To be programmed at user's discretion. This is the activation time of
the device connected between ter12V / F2. Default value = 1
second, minimum value 0,5 s., maximum value 255 s.
On entry to parameter editing mode, start the count of the time to be
memorised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at
intervals of 500ms ON/500ms OFF to enable calculation of the time
elapsed, 1 flash = 1 s. (e.g. 10 flashes = 10 s.).
Press the pushbutton END to proceed with the other parameters.
To reset the time to 0 (0.5 s.) press the pushbutton STOP/NO in place
of the pushbutton START/YES.
-
PANEL RINGTONE ENABLE
To be programmed as required. Enables repetition of the call ringtone
in the loudspeaker of the panel, from the panel where the call is being
made. Default value = enabled
On entry to parameter editing mode, press the pushbutton START/YES
to enable the function, or the pushbutton STOP/NO to disable the fun-
ction.
Press the pushbutton END (bottom left) to proceed with the other pa-
rameters.
-
PANEL LOCK BLOCK
To be programmed as required. Activation of the lock block enables
control of the lock only when the panel is in call, conversation or self-
start status. Default value = block disabled
On entry to parameter editing mode, press the pushbutton START/YES
to enable the function, or the pushbutton STOP/NO to disable the fun-
ction.
Press the pushbutton END (bottom left) to proceed with the other pa-
rameters.
-
RINGTONE CYCLES
To be programmed at user's discretion. This is the number of times that
the call is repeated in the monitor/interphone when a call pushbutton is
pressed.
Default value = 2 times, minimum value 1, maximum value 20.
On entry to parameter editing mode, start thecount of the cycles to me-
morised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at
intervals of 500ms ON/500ms OFF to enable calculation of the number
of cycles, 1 flash = 1 cycle (e.g. 5 flashes = 5 cycles).
Press the pushbutton END to proceed with the other parameters.
15
GB