RESET EEPROM
Restores all default parameter settings.
On entry to the parameter editing mode, the two red LEDs (DL1 and DL2)
will start to flash 8 times and the panel emits a continuous high tone.
During flashing, press the push-buttons PREVIOUS, OK, STOP in se-
quence to start deletion of the EEPROM. During deletion, the red LEDs
will start flashing at intervals of 100ms ON / 100ms OFF. On completion
of the deletion process, the panel exits programming mode and the mi-
croprocessor is initialised.
-
SINGLE/DOUBLE PUSH-BUTTONS
This specifies if the panel push-buttons are in single or double rows.
Default value = push-buttons in single row.
On entry to parameter editing mode, press the pushbutton START/YES
(top left) for single row push-buttons of the pushbutton STOP/NO (mid-
dle left) for push-buttons in double rows.
Press the pushbutton END (bottom left) to proceed with the other para-
meters.
-
ANSWER TIME
To be programmed as required. This is the time interval, expressed in
seconds, that the panel waits after a call has been terminated and the
time when the handset of the interphone/monitor is raised. If the handset
is not raised within this time interval, the panel disables the inter-
phone/monitor. If the handset is raised before this interval elapses, the
panel starts to count the conversation time.
Default value = 30 s., minimum value 1 s., maximum value 255 s.
On entry to parameter editing mode, start the count of the time to be
memorised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at in-
tervals of 500ms ON/500ms OFF to enable calculation of the time elap-
sed, 1 flash = 1 s. (e.g. 10 flashes = 10 s.).
Press the pushbutton END to proceed with the other parameters.
-
CONVERSATION TIME
To be programmed at user's discretion. This is the time interval, expres-
sed in seconds, that the panel checks, from the time when the handset
is raised after the call. The panel disables the internal unit after this time
interval.Default value = 12 (120 s.), minimum value 10 s., maximum value
2550 s.
On entry to parameter editing mode, start the count of the time to be
memorised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at in-
tervals of 500ms ON/500ms OFF to enable calculation of the time elap-
sed, 1 flash = 1 s. (e.g. 10 flashes = 100 s.).
Press the pushbutton END to proceed with the other parameters.
-
SELF-START TIME
To be programmed at the user's discretion. This is the time interval, ex-
pressed in seconds, that the panel remains engaged with a moni-
tor/interphone, from activation by means of the self-start function. The
panel disables the internal unit after this time interval.
Default value = 10 s., minimum value 1 s., maximum value 255 s.
On entry to parameter editing mode, start the count of the time to be
memorised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at in-
tervals of 500ms ON/500ms OFF to enable calculation of the time elap-
sed, 1 flash = 1 s. (e.g. 10 flashes = 10 s.).
Press the pushbutton END to proceed with the other parameters.
-
LOCK TIME
To be programmed at user's discretion. This is the activation time of
the lock connected between terminals S+ / S- and +12V / SR.
Default value = 1 second, minimum value 0 s., maximum value 5 s.
On entry to parameter editing mode, start the count of the time to be
memorised by means of the pushbutton START/YES. To end the count,
press the pushbutton STOP/NO. During the count, the LEDs flash at
intervals of 500ms ON/500ms OFF to enable calculation of the time
elapsed, 1 flash = 1 s. (e.g. 10 flashes = 10 s.).
Press the pushbutton END to proceed with the other parameters.
To reset the time (0 s.) press the pushbutton STOP/NO in place of the
pushbutton START/YES.
GB
14
DL3 DL4
DL5 DL6
PREVIOUS
NEXT
DL3 DL4
DL5 DL6
PREVIOUS
NEXT
DL3 DL4
DL5 DL6
PREVIOUS
NEXT
DL3 DL4
DL5 DL6
OK
END
F2
TIME
OK
END
REPEAT
PANEL RINGTONE
OK
END
LOCK
BLOCK
OK
END
RINGTONE CYCLES
PREVIOUS
NEXT
DL3 DL4
DL5 DL6
PREVIOUS
NEXT
OK
RESERVED
DL3 DL4
DL5 DL6
OK
END
RESERVED
DL3 DL4
DL6
END
PREVIOUS
NEXT
DL3 DL4
DL5 DL6
PREVIOUS
NEXT
OK
END
PUSHBUTTON
REMAPPING
DL3 DL4
DL5 DL6
OK
END
RESERVED
END
SEQUENCE
PREVIOUS