Elvo 69DM Installation And Operation Manual Download Page 7

Press 

to cancel. Press 

to confirm. As with all com-

mands, implementation is confirmed on the first line of the di-
splay.

Press 

to move on to the next item in the programming

menu.

5.7.

COMMON LOCK RELEASE 

Press 

to move to the next item and program what lock

actions the interface must notify DigiBus of. In practice the lock
release output of the DigiBus entrance panel downstream can
be activated either by a direct command or indirectly, if the lock
of another ELVOX TWO-WIRE entrance panel (up to a maxi-
mum of four) is released. This parameter is left blank by default. 

Enter a number between 1 and 15, being the ID of the entrance
panel (in this case the first of four possible choices) to whose
lock release the interface must respond. 

Press 

to cancel. Press 

to confirm. As with all com-

mands, implementation is confirmed on the first line of the di-
splay.

The display warns you if the value you enter is out of range.

Enter 0 as the ID to cancel assignment. Press 

and

to move between one identity and another. In position 1, press

to move on to the next item in the programming menu.

Press 

to skip all intermediate steps and return directly to

the previous item in the programming menu. 

5.8.

F1 COMMON 

Press 

to move to the next item and program what lock

actions the interface must notify DigiBus of. In practice the F1
output of the DigiBus entrance panel downstream can be acti-
vated either by a direct command or indirectly, if the F1 output
of another ELVOX TWO-WIRE entrance panel (up to a maxi-
mum of four) is activated. 

This parameter is left blank by default. Enter a number between
1 and 15.

Press 

to cancel. Press 

to confirm. As with all com-

mands, implementation is confirmed on the first line of the di-
splay.   

+ D

+ D

+ D

+ D

Then press 

.

To enter a number, simply key in the relevant digits.  

Press 

to delete the last digit.  

If you enter fewer than the 4 or 8 digits required, any blank spa-
ces to the left are filled with ‘0’s.

Press 

to cancel. Press 

to confirm. The programmer

now checks that the number entered is not already associated
with another position.

If it is, you are notified as follows. In this example you are war-
ned that the code 7856 is already associated with the device
identity 99. If no clashes are found, implementation of the
change is confirmed on the first line of the display.

Press 

to delete all numbers starting from the location of

the current value. 

You are asked to press 

to confirm. 

then 

. Press 

or with 

to cancel the proce-

dure. If you choose to proceed with the number reset, the di-
splay reads out:

Then, finally:

5.6.

NUMBER OF RING TONE CYCLES 

Press 

to move to the next item and change the number of

ring tone cycles sent by the interface to the ELVOX TWO-WIRE
wiring pillar.  Ring tones follow a rhythm of 1 second of sound to
2 seconds of pause, so that each complete cycle lasts 3 se-
conds. The figure shown is the current setting:

Enter a new number to change the number of cycles:

+ D

GB

7/16

69DM

Summary of Contents for 69DM

Page 1: ...Cod S6I 69D M0E RL 03 1 2012 Product is according to EC Directive 2004 108 CE 2006 95 CE and following norms GB Art 69DM INSTALLATION AND OPERATION MANUAL DIGIBUS ELVOX TWO WIRE INTERFACE...

Page 2: ...MMON F1 9 5 9 COMMON F2 9 5 10 FUNCTION ENABLING DISABLING 10 6 NUMBER CORRESPONDENCE 11 7 FUNCTION CORRESPONDENCE 11 8 FUNCTIONING WITH SWITCHBOARD 11 8 1 CALLS FROM ENTRANCE PANEL 11 8 2 INTERCOMMUN...

Page 3: ...ply is needed The 69DM interface must be assigned an identity on DIP switch S1 fig 2 There is not a theoretical limit to the maximum number of 69DM that can be connected to the DigiBus side For 2 Wire...

Page 4: ...terface Only identities between 2 and 15 can be assigned 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NON ASSEGNATO 1 2 3 4 I...

Page 5: ...r if you press the key from any of the main menu items listed below D On Off Dis Abilitazioni Italiano Lingua locale Lingua DIP SWITCH DEFAULT VOCE SUCCESSIVA VOCE PRECEDENTE SOTTO VOCE Numero cifre c...

Page 6: ...to move on to the next item in the pro gramming menu 5 4 FINAL NUMBER Press to move to the next item and change the final num ber in the DigiBus numbering range accepted by the interface This paramete...

Page 7: ...stream can be acti vated either by a direct command or indirectly if the F1 output of another ELVOX TWO WIRE entrance panel up to a maxi mum of four is activated This parameter is left blank by defaul...

Page 8: ...lock release or F1 or F2 commands You can also program the interface to command allow activation only by cer tain audio or video door entry systems To minimise the number of programming steps if the i...

Page 9: ...If the number is found in the table the corresponding index is used as desti nation Otherwise the initial and final numbers are evaluated and set respectively to 1 and 200 if not programmed If the Dig...

Page 10: ...mo nitor or interphone device has to be programmed into the 69DM If as suggested before every 69DM of the system was identified by ID 15 the programming procedure is the same for every devices Nel cas...

Page 11: ...anymore and the system can be configured in this way 5 buildings From left to right ID 1 20 1 20 1 20 1 20 1 20 5 69DM with starting finish 1 20 21 40 41 60 6 80 81 100 DIGIBUS DIGIBUS DUE FILI ELVOX...

Page 12: ...the line a jumper must be inserted according to the fol lowing rule Keep the jumper in position A if the BUS enters and exists from the device Move the jumper to position B if Elvox cable or to positi...

Page 13: ...SYSTEM WIRING PILLAR REF Si565 Mains Power supply Art 6942 Mains GB 13 16 69DM D0d Dd F Art 6922 X X X X B1 B2 B2 B3 B5 B4 B1 MONITOR SERIES 7200 Art 7211 B2 MONITOR SERIES 6600 Art 6621 662C 6721 Art...

Page 14: ...0 2 1 V 8 4 6 6 3 C 9 5 2 1 4 0 R 7 8 88888888 75 Ohm 75 Ohm CONNECTING A DIGIBUS MAIN ENTRANCE PANEL AND INTERFACE ART 69DM TO CONNECT UP ELVOX 2 WIRE SECON DARY ENTRANCE PANELS RIF Si566 Interface A...

Page 15: ...XT B1 C L P 75 Ohm 6 3 C 9 5 2 1 4 0 R 7 8 88888888 R R Line2 Interc2 In Out Interc POWER LINE 7 4 1 M 8 0 9 5 2 6 3 75 Ohm CONNECTION OF A DIGIBUS 2 WIRE SYSTEM CONSISTING OF TWO MAIN ENTRANCE PANELS...

Page 16: ...o not expose the set to dripping or sprinkling of water No objects filled with liquids such as vases should be placed on the apparatus Installers must ensure that manuals with the above instructions a...