Elvo 69DM Installation And Operation Manual Download Page 5

5. SOFTWARE CONFIGURATIONS  

With the exclusion of the interface’s ID assignment, the 950C programmer is required to perform all other configurations. The pro-
grammer is connected to connector CN4 at the top right of the unit, accessible from outside the cover. As an alternative you can
also use interfaces 692I or 692I/U and SaveProg PC software (Art. 69CD). The following parameters are configurable

:

The keys on the programmer are
arranged as follows.

The 

key serves no purpose when the programmer is po-

wered from the bus. There is no auto-shutdown function for the

same reason.  Press the 

and 

keys on the program-

mer to move to the following item in the main menu. 

The following screen is displayed while waiting for the response
from the interface:

After a few seconds, the type and version of the interface soft-
ware appear on the programmer display:

When this screen disappears, the first item in the programming
menu is displayed. The programming procedure terminates ei-

ther when timed out or if you press the 

key from any of the

main menu items listed below.

+ D

On\Off

(Dis)Abilitazioni

Italiano

(Lingua locale)

Lingua

DIP SWITCH

DEFAULT

VOCE

SUCCESSIVA

VOCE

PRECEDENTE

SOTTO

VOCE

Numero cifre

codifica

Numero iniziale

Numero finale

Numerazione

dispositivi

Numero cicli

suoneria

Serratura

comune

F1

comune

F2

comune

8

Vuoto

Vuoto

Vuota

Vuota

2

Vuota

Vuota

Vuota

200 x

O

204 x

O

4 x

O

4 x

O

4 x

O

+ D

+ D

+ D

+ D

+ D

+ D

+ D

+ D

+ D

+ D

TAB. 2

PARAMETER

NEXT 

ITEM

PREVIOUS

ITEM

SUB-

ITEM

Italian (or local
language)

Language

Number of
code digits

Initial number

Blank

Blank

Blank

Blank

Blank

Blank

Blank

Device 

numbering

Number of ring
tone cycles

Common lock
release

Final number

Common F2

Common F1

Function ena-
bling/disabling

5.1.

LANGUAGE   

The interface can be programmed to display messages in Italian
(or the local or default language) or English. Local languages vary
according to the national market. To select your language, sim-

ply press 

for the local language or 

for English.

Press 

to cancel. Press 

to confirm. As with all com-

mands, implementation is confirmed on the first line of the di-
splay.

The display language now changes. 

Press 

to move on to the next item in the programming

menu. 

GB

5/16

69DM

Summary of Contents for 69DM

Page 1: ...Cod S6I 69D M0E RL 03 1 2012 Product is according to EC Directive 2004 108 CE 2006 95 CE and following norms GB Art 69DM INSTALLATION AND OPERATION MANUAL DIGIBUS ELVOX TWO WIRE INTERFACE...

Page 2: ...MMON F1 9 5 9 COMMON F2 9 5 10 FUNCTION ENABLING DISABLING 10 6 NUMBER CORRESPONDENCE 11 7 FUNCTION CORRESPONDENCE 11 8 FUNCTIONING WITH SWITCHBOARD 11 8 1 CALLS FROM ENTRANCE PANEL 11 8 2 INTERCOMMUN...

Page 3: ...ply is needed The 69DM interface must be assigned an identity on DIP switch S1 fig 2 There is not a theoretical limit to the maximum number of 69DM that can be connected to the DigiBus side For 2 Wire...

Page 4: ...terface Only identities between 2 and 15 can be assigned 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NON ASSEGNATO 1 2 3 4 I...

Page 5: ...r if you press the key from any of the main menu items listed below D On Off Dis Abilitazioni Italiano Lingua locale Lingua DIP SWITCH DEFAULT VOCE SUCCESSIVA VOCE PRECEDENTE SOTTO VOCE Numero cifre c...

Page 6: ...to move on to the next item in the pro gramming menu 5 4 FINAL NUMBER Press to move to the next item and change the final num ber in the DigiBus numbering range accepted by the interface This paramete...

Page 7: ...stream can be acti vated either by a direct command or indirectly if the F1 output of another ELVOX TWO WIRE entrance panel up to a maxi mum of four is activated This parameter is left blank by defaul...

Page 8: ...lock release or F1 or F2 commands You can also program the interface to command allow activation only by cer tain audio or video door entry systems To minimise the number of programming steps if the i...

Page 9: ...If the number is found in the table the corresponding index is used as desti nation Otherwise the initial and final numbers are evaluated and set respectively to 1 and 200 if not programmed If the Dig...

Page 10: ...mo nitor or interphone device has to be programmed into the 69DM If as suggested before every 69DM of the system was identified by ID 15 the programming procedure is the same for every devices Nel cas...

Page 11: ...anymore and the system can be configured in this way 5 buildings From left to right ID 1 20 1 20 1 20 1 20 1 20 5 69DM with starting finish 1 20 21 40 41 60 6 80 81 100 DIGIBUS DIGIBUS DUE FILI ELVOX...

Page 12: ...the line a jumper must be inserted according to the fol lowing rule Keep the jumper in position A if the BUS enters and exists from the device Move the jumper to position B if Elvox cable or to positi...

Page 13: ...SYSTEM WIRING PILLAR REF Si565 Mains Power supply Art 6942 Mains GB 13 16 69DM D0d Dd F Art 6922 X X X X B1 B2 B2 B3 B5 B4 B1 MONITOR SERIES 7200 Art 7211 B2 MONITOR SERIES 6600 Art 6621 662C 6721 Art...

Page 14: ...0 2 1 V 8 4 6 6 3 C 9 5 2 1 4 0 R 7 8 88888888 75 Ohm 75 Ohm CONNECTING A DIGIBUS MAIN ENTRANCE PANEL AND INTERFACE ART 69DM TO CONNECT UP ELVOX 2 WIRE SECON DARY ENTRANCE PANELS RIF Si566 Interface A...

Page 15: ...XT B1 C L P 75 Ohm 6 3 C 9 5 2 1 4 0 R 7 8 88888888 R R Line2 Interc2 In Out Interc POWER LINE 7 4 1 M 8 0 9 5 2 6 3 75 Ohm CONNECTION OF A DIGIBUS 2 WIRE SYSTEM CONSISTING OF TWO MAIN ENTRANCE PANELS...

Page 16: ...o not expose the set to dripping or sprinkling of water No objects filled with liquids such as vases should be placed on the apparatus Installers must ensure that manuals with the above instructions a...

Reviews: