In this example we stopped with 9 types 69DM, but we could go on.
It is also possible to use the same numeration between main DigiBus entrance panel and secondary 2-Wire entrance panels, without
mapping again IDs. In this case the maximum number of interphones and monitors has to be 200. For example thinks to have 5 buil-
dings with 20 interphones for every building.
(5 buildings From left to right ID 1..20, 21..40, 41..60, 61..80, 81..100. 5 69DM with starting-finish 1-20, 1-40, 1-60, 1-80, 1-100).
DIGIBUSD
IG
IB
U
S
DUE FILI EL
VOX
D
U
E
F
IL
I
E
L
V
O
X
Art. 69DM
Art. 69DM
OCCUPATO
ATTENDERE
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
OCCUPATO
ATTENDERE
Art. 69DM
Art. 69DM
1 ..20
1 ..40
1 ..80
1 ..60
1 ..100
ID = 1 ..20
ID = 21 ..40
ID = 41 ..60
ID = 61 ..80
ID = 81 ..100
STARTING NUMBER - FINAL NUMBER
1 ..100
Mapping again the numeration into 2-Wire stairs entrance panels with display and keypad, the limit of 200 doesn’t exist anymore,
and the system can be configured in this way:
(5 buildings. From left to right ID 1..20, 1..20, 1..20, 1..20, 1..20. 5 69DM with starting-finish 1-20, 21-40, 41-60, 6-80, 81-100).
DIGIBUSD
IG
IB
U
S
DUE FILI EL
VOX
D
U
E
F
IL
I
E
L
V
O
X
Art. 69DM
Art. 69DM
OCCUPATO
ATTENDERE
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
Art. 69DM
OCCUPATO
ATTENDERE
Art. 69DM
Art. 69DM
ID = 1 ..20
ID = 1 ..20
ID = 1 ..20
ID = 1 ..20
ID = 1 ..20
1 ..20
21 ..40
41 ..60
61 ..80
81 ..100
STARTING NUMBER - FINAL NUMBER
1 ..100
Into the entrance panels with display and keypad is necessary for example to do the following programming:
- Stairs 3:
For ID=1 the code to be programmed is 41
For ID=2 the code to programmed is 42
For ID=20 the code to programmed is 60
- Stairs 5:
For ID=1 the code to be programmed is 81
For ID=20 the code to be programmed is 100
The push button entrance panels have not to be mapped again. The only reason to map again is if the push buttons aren’t utilized
consecutively starting from number one (it means without jumps or missing push buttons). On the contrary, you have to refer to elec-
tronic unit’s manual instructions .