33
© 2021, Elon Group AB. All rights reserved.
A (mm)
B (mm)
C (mm)
D (mm)
E
600
50 (min.)
20 (min.)
Air intake
Air outlet: 5
mm
Always ensure that the ceramic hob is correctly ventilated and
that neither the air inlet nor the air outlet are blocked. Make
sure the ceramic hob is in good condition. See below.
Note! The safe distance between hob and the cabinets
above it must be at least 600 mm.
WARNING!
Check that there is sufficient ventilation
Ensure that the ceramic hob is correctly ventilated and that
neither the air inlet nor the air outlet are blocked. To avoid
accidental contact with the hot underside of the hob (or an
electric shock when working) a wood insert must be installed
(and fixed with screws) at least 50 mm below the underside of
the hob. Follow the instructions below.
There are ventilation holes around the outside of the hob. Make sure that these holes are NOT blocked by the worktop when you
insert the hob in it.
The adhesive that is used to join plastic or wood in kitchen cabinets must be able to withstand temperatures up to 150˚C
(unsuitable adhesive could cause the material to come loose).
The wall behind the hob and any adjacent or surrounding surfaces must be able to withstand temperatures up to 90˚C.
Before fitting the clips
Place the appliance on a firm, flat surface (use the carton). Take care to
avoid damaging the controls that project from the hob. Screw the four
clips to the underside of the hob (see diagram) and fix the hob to the
work surface once it is in the correct position.
A. Screw
B. Clip
C. Screw hole
D. Base
600mm