background image

www.prolight.co.uk

Endura 18Q5 RGBW

  

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL 
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: Two years from date of purchase.

Summary of Contents for Endura 18Q5 RGBA

Page 1: ...Order code ELUM450 Endura 18Q5 RGBW Exterior Fixture User Manual ...

Page 2: ...nt and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power...

Page 3: ...features TRUE1 and 5 pin DMX inputs and outputs to facilitate a problem free connection 18 x 5W quad colour LEDs RGBW Beam angle 20 4 126 Lux 2m full on 3 6kHz refresh rate DMX channels 1 4 8 or 9 selectable Static colour colour change colour fade and master slave modes 0 100 8 or 16 bit dimming and variable strobe Bracket allows for multiple rigging or floor standing applications 4 button backlit...

Page 4: ... 1 x PowerCON TRUE1 cable 1 x user manual Fuse The Endura 18Q5 RGBW is fitted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture pl...

Page 5: ...RB Magenta RGBW Full on BLAC Blackout F000 F255 Static Colour Mode 02 FADE SP00 SP99 F000 F255 Colour Fade Mode 03 CHANG SP00 SP99 F000 F255 Colour Change Mode Manual R G B W STR Dim 000 255 Manual Dimming Mode Macros 00 63 Colour Macros NO DMX Hold Blackout DMX Fail Setting Temp C F Fixture Temperature WhiteBal R G B W 000 255 White Balance Setting AutoLock OFF ON Auto Lock Menu Setting Op Time F...

Page 6: ...ction 1 000 255 Red dimmer 0 100 2 000 255 Green dimmer 0 100 3 000 255 Blue dimmer 0 100 4 000 255 White dimmer 0 100 5 000 255 Strobe slow fast 6 000 255 Master dimmer 0 100 7 000 255 Dimmer fine 8 000 004 No function 005 125 Colour change slow fast 126 255 Colour fade slow fast 9 000 045 Linear Halogen Dimming Curves 046 075 Square 076 105 Inverse Square 106 135 S Curve 136 165 Linear LED Dimmi...

Page 7: ... DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX address...

Page 8: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Page 9: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally...

Page 10: ...www prolight co uk Endura 18Q5 RGBW User Manual 10 ...

Page 11: ...www prolight co uk Endura 18Q5 RGBW User Manual 11 ...

Page 12: ...www prolight co uk Endura 18Q5 RGBW User Manual 12 ...