background image

www.prolight.co.uk

Endura 18Q5 RGBW

  

User Manual

7

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Summary of Contents for Endura 18Q5 RGBA

Page 1: ...Order code ELUM450 Endura 18Q5 RGBW Exterior Fixture User Manual ...

Page 2: ...nt and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power...

Page 3: ...features TRUE1 and 5 pin DMX inputs and outputs to facilitate a problem free connection 18 x 5W quad colour LEDs RGBW Beam angle 20 4 126 Lux 2m full on 3 6kHz refresh rate DMX channels 1 4 8 or 9 selectable Static colour colour change colour fade and master slave modes 0 100 8 or 16 bit dimming and variable strobe Bracket allows for multiple rigging or floor standing applications 4 button backlit...

Page 4: ... 1 x PowerCON TRUE1 cable 1 x user manual Fuse The Endura 18Q5 RGBW is fitted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture pl...

Page 5: ...RB Magenta RGBW Full on BLAC Blackout F000 F255 Static Colour Mode 02 FADE SP00 SP99 F000 F255 Colour Fade Mode 03 CHANG SP00 SP99 F000 F255 Colour Change Mode Manual R G B W STR Dim 000 255 Manual Dimming Mode Macros 00 63 Colour Macros NO DMX Hold Blackout DMX Fail Setting Temp C F Fixture Temperature WhiteBal R G B W 000 255 White Balance Setting AutoLock OFF ON Auto Lock Menu Setting Op Time F...

Page 6: ...ction 1 000 255 Red dimmer 0 100 2 000 255 Green dimmer 0 100 3 000 255 Blue dimmer 0 100 4 000 255 White dimmer 0 100 5 000 255 Strobe slow fast 6 000 255 Master dimmer 0 100 7 000 255 Dimmer fine 8 000 004 No function 005 125 Colour change slow fast 126 255 Colour fade slow fast 9 000 045 Linear Halogen Dimming Curves 046 075 Square 076 105 Inverse Square 106 135 S Curve 136 165 Linear LED Dimmi...

Page 7: ... DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX address...

Page 8: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Page 9: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally...

Page 10: ...www prolight co uk Endura 18Q5 RGBW User Manual 10 ...

Page 11: ...www prolight co uk Endura 18Q5 RGBW User Manual 11 ...

Page 12: ...www prolight co uk Endura 18Q5 RGBW User Manual 12 ...

Reviews: