Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 110~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: Two years from date of purchase.

Summary of Contents for ELUM111

Page 1: ...Order code ELUM111 TZ 250PC WW User Manual ...

Page 2: ...short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 110 240V AC 50 60Hz ...

Page 3: ...e beam angle 15 36 32 420 Lux 2m full on 3 6kHz refresh rate Motorised zoom DMX channels 2 or 3 selectable 0 100 dimming and variable strobe 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display PowerCON input output 5 Pin XLR input output 3 Pin XLR input output Filter frame and barn doors included TZ 250PC WW Specifi...

Page 4: ...C 09 10 11 03 03 02 12 13 14 05 06 07 01 08 04 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 Function knobs 05 3 Pin DMX input 06 3 Pin DMX output 07 5 Pin DMX input 08 5 Pin DMX output 09 PowerCON input 10 PowerCON output In the box 1 x fixture 1 x barn doors 1 x PowerCON cable 1 x user manual 11 Fuse T3A 250V 12 Barn doors 13 Hanging bracket 14 Hanging bracket adj...

Page 5: ...X Channel 03CH NoDMX Mode NoDMX Mode Hold NoDMX Mode Close Blackout if no DMX signal present Hold last command Dormancy Dormancy 00 Dormancy 99 Last command hold 0 mins 9 mins Backlight Backlight 02 Backlight 60 Backlight 02 mins 60 mins Fan Set Fan Set Auto Fan Set Low Fan speed Fan Set High Dim Curve Dim Curve Linear Dim Curve INV Square Dim Curve Square Dimmer Curves Dim Curve S Curve ...

Page 6: ... Error Info Model Info Elumen8 Software V Panel Ctrl Dim 000 Panel Ctrl Dim 255 Panel Ctrl Panel Ctrl Focus 000 Panel Ctrl Focus 255 Brightness beam angle Calibrate Calibrate Focus 000 Calibrate Focus 255 Calibrate focus MENU CONT Lamp Behaviour Lamp Behaviour LED Lamp Behaviour Halogen LED Halogen selection ...

Page 7: ...R button to confirm the setting To exit out of any of the above options press the MENU button To choose what the fixture does when it loses DMX signal press the MENU button on the front of the unit to show NoDMX Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to choose between Hold or Close Press the ENTER button to confirm the setting If you choose HOLD press th...

Page 8: ... of the unit to show Calibrate on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the focus from 000 255 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Dimming curves To access the units dimmer curves press the MENU button on the rear of the unit to show Dim Curve on the LCD display Press the ENTER button an...

Page 9: ...X is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing...

Page 10: ... pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advi...

Page 11: ...ible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally s...

Page 12: ...www prolight co uk TZ 250PC WW User Manual 12 ...