www.prolight.co.uk
TZ 250PC WW
User Manual
7
DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of the
fixture and each fixture independently.
To access the DMX address mode, press the
“MENU”
button on the front of the unit to show
“DMX MODE ADDR:”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to set the required DMX address. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
To access the DMX channel mode, press the
“MENU”
button on the front of the unit to show
“DMX Channel”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to set the required DMX channel. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
To choose what the fixture does when it loses DMX signal, press the
“MENU”
button on the front of the
unit to show
“NoDMX Mode”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to choose between
“Hold”
or
“Close”
. Press the
“ENTER”
button to confirm the setting.
If you choose
“HOLD”
press the
“MENU”
again to show
“Dormancy”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to set how long the fixture holds the last DMX
signal for, from
“00” - “99”
. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
Operating instructions
Channel Value
Function
1
000-255 Focus (8 bit)
2
000-255 Master dimmer (0-100%)
2 channel mode:
Channel Value
Function
1
000-255 Focus (8 bit)
2
000-255 Master dimmer (0-100%)
3
000-063 LED on
064-095 Strobe (slow-fast)
096-127 LED on
128-159 Strobe pulse (slow-fast)
160-191
LED on
192-223 Random strobe (slow-fast)
224-255 LED on
3 channel mode: