Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Summary of Contents for ELUM111

Page 1: ...Order code ELUM111 TZ 250PC WW User Manual ...

Page 2: ...short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 110 240V AC 50 60Hz ...

Page 3: ...e beam angle 15 36 32 420 Lux 2m full on 3 6kHz refresh rate Motorised zoom DMX channels 2 or 3 selectable 0 100 dimming and variable strobe 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display PowerCON input output 5 Pin XLR input output 3 Pin XLR input output Filter frame and barn doors included TZ 250PC WW Specifi...

Page 4: ...C 09 10 11 03 03 02 12 13 14 05 06 07 01 08 04 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 Function knobs 05 3 Pin DMX input 06 3 Pin DMX output 07 5 Pin DMX input 08 5 Pin DMX output 09 PowerCON input 10 PowerCON output In the box 1 x fixture 1 x barn doors 1 x PowerCON cable 1 x user manual 11 Fuse T3A 250V 12 Barn doors 13 Hanging bracket 14 Hanging bracket adj...

Page 5: ...X Channel 03CH NoDMX Mode NoDMX Mode Hold NoDMX Mode Close Blackout if no DMX signal present Hold last command Dormancy Dormancy 00 Dormancy 99 Last command hold 0 mins 9 mins Backlight Backlight 02 Backlight 60 Backlight 02 mins 60 mins Fan Set Fan Set Auto Fan Set Low Fan speed Fan Set High Dim Curve Dim Curve Linear Dim Curve INV Square Dim Curve Square Dimmer Curves Dim Curve S Curve ...

Page 6: ... Error Info Model Info Elumen8 Software V Panel Ctrl Dim 000 Panel Ctrl Dim 255 Panel Ctrl Panel Ctrl Focus 000 Panel Ctrl Focus 255 Brightness beam angle Calibrate Calibrate Focus 000 Calibrate Focus 255 Calibrate focus MENU CONT Lamp Behaviour Lamp Behaviour LED Lamp Behaviour Halogen LED Halogen selection ...

Page 7: ...R button to confirm the setting To exit out of any of the above options press the MENU button To choose what the fixture does when it loses DMX signal press the MENU button on the front of the unit to show NoDMX Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to choose between Hold or Close Press the ENTER button to confirm the setting If you choose HOLD press th...

Page 8: ... of the unit to show Calibrate on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the focus from 000 255 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Dimming curves To access the units dimmer curves press the MENU button on the rear of the unit to show Dim Curve on the LCD display Press the ENTER button an...

Page 9: ...X is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing...

Page 10: ... pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advi...

Page 11: ...ible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally s...

Page 12: ...www prolight co uk TZ 250PC WW User Manual 12 ...

Reviews: