background image

www.prolight.co.uk

DB1300 DMX Stage Blinder

  

User Manual

8

DMX dipswitch quick reference chart

DMX DIPSWITCH SET

0 = OFF

1 = ON

#9

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

#8

0

0

0

0

1

1

1

1

0

0

0

0

1

1

1

1

#7

0

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

#6

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

#1

#2

#3

#4

#5

0

0

0

0

0

32

64

96

128 160 192 224 256 288 320 352 384 416 448 480

1

0

0

0

0

1

33

65

97

129 161 193 225 257 289 321 353 385 417 449 481

0

1

0

0

0

2

34

66

98

130 162 194 226 258 290 322 354 386 418 450 482

1

1

0

0

0

3

35

67

99

131 163 195 227 259 291 323 355 387 419 451 483

0

0

1

0

0

4

36

68

100 132 164 196 228 260 292 324 356 388 420 452 484

1

0

1

0

0

5

37

69

101 133 165 197 229 261 293 325 357 389 421 453 485

0

1

1

0

0

6

38

70

102 134 166 198 230 262 294 326 358 390 422 454 486

1

1

1

0

0

7

39

71

103 135 167 199 231 263 295 327 359 391 423 455 487

0

0

0

1

0

8

40

72

104 136 168 200 232 264 296 328 360 392 424 456 488

1

0

0

1

0

9

41

73

105 137 169 201 233 265 297 329 361 393 425 457 489

0

1

0

1

0

10

42

74

106 138 170 202 234 266 298 330 362 394 426 458 490

1

1

0

1

0

11

43

75

107 139 171 203 235 267 299 331 363 395 427 459 491

0

0

1

1

0

12

44

76

108 140 172 204 236 268 300 332 364 396 428 460 492

1

0

1

1

0

13

45

77

109 141 173 205 237 269 301 333 365 397 429 461 493

0

1

1

1

0

14

46

78

110 142 174 206 238 270 302 334 366 398 430 462 494

1

1

1

1

0

15

47

79

111 143 175 207 239 271 303 335 367 399 431 463 495

0

0

0

0

1

16

48

80

112 144 176 208 240 272 304 336 368 400 432 464 496

1

0

0

0

1

17

49

81

113 145 177 209 241 273 305 337 369 401 433 465 497

0

1

0

0

1

18

50

82

114 146 178 210 242 274 306 338 370 402 434 466 498

1

1

0

0

1

19

51

83

115 147 179 211 243 275 307 339 371 403 435 467 499

0

0

1

0

1

20

52

84

116 148 180 212 244 276 308 340 372 404 436 468 500

1

0

1

0

1

21

53

85

117 149 181 213 245 277 309 341 373 405 437 469 501

0

1

1

0

1

22

54

86

118 150 182 214 246 278 310 342 374 406 438 470 502

1

1

1

0

1

23

55

87

119 151 183 215 247 279 311 343 375 407 439 471 503

0

0

0

1

1

24

56

88

120 152 184 216 248 280 312 344 376 408 440 472 504

1

0

0

1

1

25

57

89

121 153 185 217 249 281 313 345 377 409 441 473 505

0

1

0

1

1

26

58

90

122 154 186 218 250 282 314 346 378 410 442 474 506

1

1

0

1

1

27

59

91

123 155 187 219 251 283 315 347 379 411 443 475 507

0

0

1

1

1

28

60

92

124 156 188 220 252 284 316 348 380 412 444 476 508

1

0

1

1

1

29

61

93

125 157 189 221 253 285 317 349 381 413 445 477 509

0

1

1

1

1

30

62

94

126 158 190 222 254 286 318 350 382 414 446 478 510

1

1

1

1

1

31

63

95

127 159 191 223 255 287 319 351 383 415 447 479 511

Operating instructions

Summary of Contents for DB1300

Page 1: ...Order codes ELUM065 DB1300 DMX Stage Blinder User Manual ...

Page 2: ... immediately and have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly st...

Page 3: ...g the supplied mounting bracket In order to safeguard sufficient ventilation leave 0 5m of free space around the device The housing must never touch surrounding surfaces or objects Always secure the fixture with an appropriate safety wire as a security safety measure Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PAR...

Page 4: ... type and rating Before replacing the fuse unplug the mains lead To replace the fuse follow the procedure below Step 1 Unscrew the fuse holder on the rear panel with an appropriate screwdriver from the housing anti clockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and screw it back in OPERATING DET...

Page 5: ...not supplied Beam angle 40 x 30 7699 Lux 2m full on DMX channels 1 Dimming auto and master slave modes Dipswitch mode address selection 0 100 dimming Captive power connection fitted with a 13A UK plug 3 Pin XLR input output Convection cooled DB1300 DMX 2 Cell Stage Blinder Specifications DB1300 Stage Blinder Power consumption 1320W Max ambient temperature Ta 45 C Max distance from flammable surfac...

Page 6: ...g replacing the lamp make sure the fixture is off and disconnected form the mains Keep away from rain and moisture Lamp 2 x Par 36 650W 120V DWE Duty cycle 1 minute full on 3 minutes rest Ta 45 C TC 410 C DMX pinout 1 Ground 2 Signal 3 Signal 09 01 06 07 02 03 05 04 09 Technical specifications 01 Earth point 02 Dipswitches 03 DMX signal indicator 04 3 Pin DMX input 05 3 Pin DMX output 06 Captive p...

Page 7: ...ure by changing the dipswitches as set out in the table below The starting address is defined as the first channel from which the device will respond to the controller Please make sure that you do not have any overlapping channels in order to control each fixture correctly and independently from any other fixture on the DMX data link If two three or more devices are addressed similarly they will w...

Page 8: ...92 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274...

Page 9: ...king DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX add...

Page 10: ...L89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always...

Page 11: ...t possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environment...

Page 12: ...iler to purchase these accessories To keep up to date on the latest accessories and product range additions please visit www prolight co uk Par 36 650W 120V DWE Lamp Order code LAMP91 50mm Professional G Clamp Order code CLAM01A Self Locking Truss Clamp Black Order code GL3017 75cm Safety Wire Order code CLAM03 ...

Reviews: