WEP-2L. User manual
41
•
•
5.7.2 The «Access» submenu
In the
«Access»
submenu, you can configure access to the device via the web interface, Telnet, SSH, NETCONF
and SNMP.
To enable access to the device via the web interface via HTTP protocol, set the flag next to «WEB». In the
window that appears, it is possible to change the HTTP port (by default, 80). The range of acceptable values
of ports, in addition to the default, from 1025 to 65535 inclusive;
To enable access to the device via the web interface via HTTPS protocol, set the flag next to «WEB-HTTPS».
In the window that appears, it is possible to change the HTTPS port (by default, 443). The range of
acceptable values of ports, in addition to the default, from 1025 to 65535 inclusive;
WEP-2L
software allows monitoring status of the device and it's sensors via SNMP. In the SNMP submenu, you
can configure settings of SNMP agent. The device supports SNMPv1 and SNMPv2 protocol version.
To change the SNMP settings, check the box next to «SNMP», apply the configuration and then go to the SNMP
submenu.
Note that the ports for the HTTP and HTTPS protocols should not have the same value.